ATC Environmental, Inc.
1 104 East 25th Street
New York, New York 10010
ATC Associates Inc. Approved N.Y. State ELAP #10879
104 East 25th Street ACCREDITED NVLAP Lab Code # 1187
New York, NY 10010 Report Date: 10/25/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
With Fiber Identification by Selected-Area Electron Diffraction (SHED; and Energy-Dispersive X-RAY Spectroscopy ZEDS)
Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763; , Vcl. 52, No. 210, October 30, 1937
1 Sample Identification Analysis Parameters
Project/Site: Related, Tribeca T.R. 105 Duane St., NY, NY TEN Sample No. : 5761 - 62181
Various Sites
Date Received: 10/25/01 Grid Openings Analyzed: 6
Project Sample No.: 08 Average Grid Opening: 106.00 um
Air Volume: 1300 liters Total Area Analyzed: 0.0674 mm2
Filter Type: MCE 25 mm diem., Pore Size: 0.45 um Analytical Sensitivity: 14.8 s/mm2
Effective Area: 385 mm2 0.0044 s/cc
----------------------------------------------------------------------------------------------------------------------------------
FIBROUS PARTICULATES ANALYZED
Number Observed CONCENTRATION
Total
Single Matrix Total. Struct. Filter Air
Fibers Bundles Clusters Struct. Struct. >=Sum Struct/mm2 Struct/cc nom/m3
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 C 0.0 0.0000 0
Ambiguous 0 J 0 C 0 0 0.0 0.0000 0
I Total asbestos (includes ambiguous structures)
Non-Asbestos
No Identification
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0000
0.0000
0.0000
0
N/A
N/A
Totals (All Structures) 0 0 0.0 0.0000 N/A
The estimated uncertainty of this analysis is 1 standard deviat-on..
----------------------------------------------------------------------------------------------------------------------------------
' --------------------------------------------------------------
Non -asbestos fiber i.d. (EDS/SAED): None detected
Amphibole Asbestos Type: None detected
1 The Analysis was carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method.
Analyzed by: Report Reviewed by:
Roman Peysakhov Michael A. Gorycki, Ph.D.
Director of Electron Microscopy
NYC-WTC 000104148