Environmental Site Characterization — Facade Report (J
Fiterman Hall — 30 West Broadway, New York, NY
Airtek Project 05-0867 — January 10, 2006
J
Protection (NYCDEP), Section I-53; the New York State Department of Labor
(NYSDOL) Industrial Code, Rule 56: Asbestos Regulation, Title 15, Sections 56-
1.4 and 56-1.9(e); and the U.S. EPA National Emissions Standards for Hazardous
Air Pollutants (NESHAP) for asbestos-containing building materials (ACBM).
The requirement for an asbestos building survey includes the requirement that the
building facade be investigated for ACBMs. The facade ACBM survey was
conducted by NYS DOL Certified Asbestos Inspectors.
2.5 Lead-Based Paint Survey
Although recently renovated, Fiterman Hall was built in the 1950's. USEPA
Certified Lead Inspectors conducted testing of building components throughout
the structure. Testing of building components included the testing of facade
components. This effort provided data in support of decisions related to building
materials handling, waste characterization and waste management.
2.6 WTC COPC Impact Investigation
Contaminants of Potential Concern:
Following the WTC Event, the U.S. EPA established a committee to evaluate
Contaminants of Potential Concern (CoPCs) found in WTC dust. TheICoPC
Committee of the World Trade Center Indoor Air Task Force Working Group
prepared the World Trade Center Indoor Environment Assessment: Selecting
Contaminants of Potential Concern and Setting Health-Based Benchmarks (May
2003), which identified the compounds of concern for Lower Manhattan cleanup
efforts. The WTC Dust Characterization for CoPCs, as defined by the U.S.
EPA's COPC Committee, are Silica, Polycyclic Aromatic hydrocarbons (PAHs),
Dioxin, Polychlorinated Biphenyls (PCBs), Heavy Metals (Barium, Beryllium,
Cadmium, Chromium, Copper, Lead, Manganese, Nickel, and Zinc), and
Mercury.
Surface Impact:
Airtek conducted a thorough visual inspection of the building facade, and
conducted interviews with NYC DEP personnel with knowledge of the previous
exterior cleaning that was conducted under the NYC DEP exterior cleaning
program. As confirmation of the findings of that investigation. Airtek collected
samples to determine the CoPC surface concentration at various exterior facade
locations.
Interstitial Impact:
A component of the review of existing documentation included a review of
drawings for potential communicating openings and interstices that could have
been impacted by WTC CoPCs. In addition to the documentation review,
confirmatory destructive investigations of the facade, its structure and
its
components were conducted.