NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 02/30 West Broadway
Document / 56 pages

Preliminary Environmental Assessment report, Jan 2006

Machine-extracted title · confidence 90%

Cover page for a Preliminary Environmental Assessment report dated January 10, 2006 for 30 West Street.

NYC-WTC_000095688–000095743

Folder label: “30 West Broadway

Page image
Scanned page image, NYC-WTC_000095691
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Environmental Characterization Report Fiterman Hall, 30 West Broadway, New York, NY Airtek Project #05-0867 — January 10, 2006

need to expend time and resources delineating contaminated versus uncontaminated materials and spaces. The investigation therefore focuses on the nature of the Building materials, other materials and objects that remain within the Building and the structure and lay-out of the Building as it relates to the remediation and deconstruction process.

This investigation concludes that an environmental remediation involving the removal of all non-structural components remaining within the building, followed by a thorough cleaning and encapsulation of all remaining structural components is the safest and most efficient means to prepare the building for deconstruction.

In brief, other conclusions of note include the following:

Asbestos Monitoring: Testing conducted as required by the New York State Department of Labor under Industrial Code Rule 56 (56-17), indicates that the installation and operation of the site access facility at the northwest corner of the building has not resulted in the release of asbestos to the outside of the building. All sample results are within acceptable limits.

Personal Exposure Testing: The results of personal exposure sampling conducted to date indicate that the personal protective equipment specified in the original site Health & Safety Plan is sufficient personal protection for the contaminants tested for during the activities conducted to date.

Exterior Facade: Cleaning of the exterior facade of the Building conducted by the NYC DEP as a part of its WTC response was effective, and re-cleaning of the majority of the facade is not necessary or advisable. Cleaning of the lower two floors where urban background road dust has accumulated will be conducted, and focused cleaning of limited facade components that exhibit residual dust will be conducted as a part of the remediation/deconstruction Project. A more detailed discussion of facade conditions and their impact on the Project can be found in a companion document, Facade Characterization Report, December 23, 2005.

Asbestos-Containing Building Materials: While extensive abatement of asbestos-containing

4

NYC-WTC 000095691

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000095691Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →