NYC 9/11 Public Portal Document
Environmental Characterization Report
Fiterman Hall, 30 West Broadway, New York, NY
Airtek Project #05-0867 — January 10, 2006
3.0 Purpose and Objectives of Current Investigation
DASNY/CUNY is committed to ensuring that appropriate
safeguards are put in place at 30 West
Broadway during the deconstruction process to
protect workers and to prevent release of the
contaminants that may be present into the surrounding
community and the environment. The
Characterization Study was conducted as the first step in the
remediation and deconstruction
process for this building.
An Asbestos Building Inspection and Material
Survey was required to facilitate the proposed
deconstruction of the Building and to comply with: (1) the New
York City Department of
Buildings (NYC DOB) permitting requirements, and
(2) the pre-demolition requirements
promulgated by the New York City Department of
Environmental Protection (NYCDEP), Section
1-53; the New York State Department of Labor
(NYSDOL) Industrial Code, Rule 56: Asbestos
Regulation, Title 15, Sections 56-1.4 and 56-1.9(e);
and the U.S. EPA National Emissions
Standards for Hazardous Air Pollutants (NESHAP)
for asbestos-containing materials (ACM).
In addition to the asbestos survey, the specific
objectives of this Characterization Study include:
• Conducting monitoring of the impact to the outside
environment of entry to the
building (per NYS DOL approved variance);
• Gathering the necessary exposure data related to the
types and levels of air
contaminants present prior to building cleaning and
deconstruction that may be
encountered by workers carrying out activities at the site
during deconstruction
and Providing data that may be applied to
choosing the appropriate levels of
worker protection at the site;
• Determining the physical and environmental condition
of the facade and its
components, as the facade an integral part of the engineering control
systems
is
that will be used to safeguard the surrounding
community and the environment;
• Providing pre-demolition background data for the site
and surrounding
environment;
NYC-WTC 000096574
OCR can misread numbers and units. Confirm readings against the page image before using them.