NYC 9/11 Public Portal Document
Regulatory Submittal Part II -
Environmental Community Air Monitoring Program
Fiterman Hall — 30 West Broadway
Airtek Project 05-0867 — January l0, 2006
3.2 Community Air Monitoring
Prior to the commencement of any site work, one week of background community
air monitoring will be conducted as detailed in Table 1— Community Air
Monitoring in Attachment A (Community Monitoring) to this specification.
Community Air Monitoring as detailed in Table 1 will continue through the
Remediation Phase and until completion of the Deconstruction Phase.
Community Monitoring locations will be determined in cooperation with the
USEPA, and will be identified on a drawing to be included in Attachment C
(Monitoring Locations) to this specification.
If the environmental air monitoring locations need to be changed during the
Remediation phase due to site conditions, NYS DOL and USEPA Region 2 office
will be notified promptly. The community air monitoring locations will not be
moved until NYS DOL and the USEPA Region 2 office accept the change.
3.3 Abatement Work Area Monitoring
Air monitoring per the requirements of NYRR ICR 56 will be conducted.
Transmission Electron Microscopy (TEM) will be utilized as the analytical
method for asbestos. Sample locations will be selected by the SH in accordance
with ICR 56-17, and based on the configuration of the abatement containment
areas. Containment area monitoring of additional Contaminants of Potential
Concern (CoPCs) that are not regulated under ICR-56 will be conducted by the
Owner's EC. The COPCs to be monitored are: Asbestos (TEM), Metals (ICP-
AES) and crystalline silica (XRD).
This monitoring is detailed in Table 3 -Abatement Work Area Monitoring in
Attachment B (Work Area Monitoring) to this specification.
4.0 Deconstruction Phase Air Monitoring
4.1 Visible Emissions
Monitoring for visible emissions will be conducted as described above in Section
2.0 of this specification.
4.2 Community Air Monitoring
Community Air Monitoring will be conducted as detailed in Table 1— Community
Air Monitoring in Attachment A (Community Monitoring) to this specification.
Community Air Monitoring will continue through the completion of the
Deconstruction Phase.
NYC-WTC 000095770