Environmental Characterization Report
Fiterman Hall. 30 West Broadway, New York, NY
Airtek Project #05-0867 — January 10, 2006
While limited visible mold does exist, it will have little or no impact on the planning and execution of
the environmental remediation and deconstruction of the building.
2.0 Previous Environmental Investigations
2.1 Pre-9/11 Asbestos and Lead Reports
In support of the gut renovation that was conducted and nearly completed at Fiterman Hall
from 2000 through September 11, 2001, limited ACBM & LBP surveys were conducted.
These surveys identified materials that were then subject to abatement during the gut
renovation. For the purpose of this study, records of the survey reports and records of the
abatement projects conducted in support of the renovations were reviewed. The primary
focus of the pre 9/1 l abatement projects was ACBM piping insulation on thermal systems.
Extensive abatement of these materials was conducted.
2.2 Post 9/11 Environmental Investigations
Following 9/11/01, several consultants were engaged to conduct testing to gauge the
environmental impact to Fiterman Hall. Sampling conducted by Applied Technology
Services ("ATS"), Howard Bader Consultants ("Bader"), and Tiffany-Bader Environmental,
Inc. ("TBE") ("the Environmental Consultants"), confirmed the presence of a wide array of
contaminants throughout the Building. The contaminants detected included asbestos, lead,
dioxin, heavy metals, mercury, fungi, bacteria, and particulate dust. Other contaminants
known to be associated with the WTC dust that can be presumed to exist in areas of Fiterman
Hall include polycyclic aromatic hydrocarbons (PAHs), and polychlorinated biphenyls
(PCBs). The results of these efforts support the conclusion that the entire structure should be
assumed to be contaminated.
In 2002, Airtek was engaged to gather and format the environmental data generated and to
review the type and extent of contamination reported by the Environmental Consultants.
NYC-WTC 000095693