NYC 9/11 Public Portal Document
Environmental Characterization Report
Fiterman Hall, 30 West Broadway, New York, NY
Airtek Project #05-0867 — January 10, 2006
building materials (ACBMs) was conducted as a part of the prior renovations to the facility, some
ACBMs remain that will be abated during the environmental Remediation Phase of the project. Non-
friable ACBM spandrel flashing within the facade will be abated during the Deconstruction Phase of
the Project.
Lead-Based Paint: A survey for lead-based paint (LBP) conducted throughout the facility has
determined that the Building is essentially lead-paint free. Only very limited lead-painted materials
remain in the facility. This includes testing of structural steel where it is accessible for testing.
Contaminants of Potential Concern: Visual inspection and limited testing for the residual impact
of WTC Contaminants of Potential Concern (CoPCs) was conducted within the Building. This testing
was intended to be illustrative of conditions, and useful in verification of some aspects of the HASP
for the site. The Building is assumed to be contaminated based on the nature of the WTC impact, and
the results of prior investigations.
Waste Characterization: Preliminary testing of WTC dust within the building will be conducted to
identify areas of the building where concentrations of RCRA — regulated contaminants within WTC
dust may exist. These preliminary results will be used to guide decisions on testing and management
of building contents and components impacted by the dust. Waste characterization for purposes of
informing decisions on waste handling, packaging, transport and disposal is to be addressed in a
companion document, Regulatory Submittal Part 7V - Waste Sampling and Management Plan
(WSMP), to be submitted with the regulatory submittals for the project. Waste characterization is an
aspect of the project to be very closely monitored by the regulatory community, and is work that will
be subject to a Quality Assurance Project Plan (QAPP). As such, it is recommended that the testing
supporting this aspect of the project be conducted after review and approval of the WSMP and its
associated QAPP by the Regulators.
Microbiological Contamination: Visual inspections for mold impact were conducted, and are
ongoing as conditions change within the building over time. In general, mold impact is limited to the
upper floors, and is most prevalent on the south side of the building where the facade was destroyed.
5
NYC-WTC 000096571
OCR can misread numbers and units. Confirm readings against the page image before using them.