NYC-WTC_000095100
ENVIROSCIENCE
CON
2.150 SMITHTOWN AVENUE
NKONKOMA, New YORK 11779
Ro
FACSIMILE: (63 f) 5803195
WWW.ENVIROHEALTH.ORG
TEM AIR SAMPLE RESULTS
SULTANTS, INC. (CLIENT: Tech Clean SAMPLE DATE: September 24, 2001
PROJECT NAME: AMEX 22 Thames
RECEIVED DATE: September 25, 2001
Ambient
B. Gallagher
B-06-05
PHONE; (631) 5803191 AREA:
Stb Floor SAMPLER:
CLIENT #: 00-10233 CUSTODY #:
89/28/2821 18:14
NYC 9/11 Public Portal Document
ELAP # 11681
NVLAP #20053 1.0 ween oe —— -
i Sample # Sample Location _ Surt i Enid | Run Time Flow Rate Vohune | Rilter Conc.| Sensitivity | Air Coac.
_ a minutes | Avg. | Liters Sénm2 Séoo Skee
TEM A28.. Elevator lobby oe 24:23; 00:47! 198 | 85 1658 0.0 0.0029
TEM. A29: Hall by room 307 cee eee vere cee BES 0040, 196. | 8.5_| 1666 9.0 0.0029
TEM A30! Hall by room 520 2asivoat! iso | 5 | 1666 | 00 | goo
TEM A31. Room $24 12126! 0042! 196 | 85 | 1666 1 00 6,0029_| <Sensitivity |
{TEM A32'Fan room 509
[TEM 33 Outside room SIL — 230i one; to | 7 | 337 | oo | e036
| a ee cone ode we ome
~ ieee et eheenee pony
s
te.
i
:
i i et cess ne nee se eee we sened -
257 S=Asbestes stnictures,co=cubic centimeters, mme=millimeier
Analyzed by: eC 7 Sette Date Analyzed: 727°C "tose than, Flow Rats afters per unas
Samples were analyzed using Philips 400T Transmission Electron Microscope. Asbestos Identification is determined by the morphology, visual Sefocted Area Electron
Diffraction (SAED), and Elemental Analysis using an Encrgy Dispersive X-ray Analyzer (EDAX).
Concentration on the filter is calculated by taking the number of asbestos structures and dividing by the arca analyzed. Aix concentration is calculated by multiplying
the effective filter area (EFA) by the filter concentration and then dividing by the volume of air collected in cubic centimeters (cc).
The data pertaining to thes calculations can he found oa the Acbestos Count Sheet,
The ais filter concentration relates only to air fiber content. When samples are submitted by an outside agency for analysis, Enviroscience. can oly guarantee the
accuracy of the filter concentration. This report may not be reproduced without the express permission of Envirosclence. This report can not be used to claim
endorsement of products by NVLAP or any agency of the US. Goverment.
‘Tha samples coflected in the responce action sree demonstrated a filter concentration of asbestes less than seventy structutes por square millimeter. This response
action is considered complete according to EPA 40 CFR 763. :
A result of zero structures per square millimeter is only applicable to the area analyzed. Test results only reflect conditions at the time samples were taken.
6315883195
ENVIROSCIENCECNSL TAN
PAGE 17
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000095100Source: NYC Law Department, mirrored locally
57-page lab report documenting World Trade Center environmental test results distributed to multiple federal, state, and local agencies including CDC and EPA.