DEP laboratory report of GCMS calibration analysis for sample AE06800 conducted on April 10, 2002.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗Laboratory report documenting GCMS analysis of environmental sample AE06049 conducted on April 5, 2002.
NYC-WTC_000060120–000060126Folder label: “GCMS X 3/15/02 A 4/6/02”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document Quantitation Report (Not Reviewed) Data File C:\MSDCHEM\l\DATA\04 0502\C25^4 05. D Vial: 52 Acq On 5 Apr 2002 9:16 pm Operator: Bohlk Sample C25 Inst ■: Instrumen Mise Multiplr: 1.00 MS Integration Params: BENZO.P Quant Time: Apr 08 05:16:09 2002 Quant Results File: 5080402.RES
Quant Method : C:\MSDCHEM\l\5973N\5080402.M (RTE Integrator) Title : Quantitation For Method 508gcscan Last Update : Fri Apr 05 05:56:22 2002 Response via : Initial Calibration DataAcq Meth : 508SCAN
Internal Standards R.T. Qlon Response Cone Units Dev(Min)
1) 1,4-Dichlorobenzene-d4 9.47 152 1489218 20.00 ug/L 0.00 10) Naphthalene-d8 12.94 136 6282571 20.00 ug/L 0.00 17) Acenaphthene-dlO 18.06 164 3361002 20.00 ug/L 0.00 29) Phenanthrene-dlO 22.42 188 4954410 20.00 ug/L 0.00 38) Chrysene-dl2 30.25 240 3470595 20.00 ug/L 0.00 44) Perylene-dl2 34.12 264 2033822 20.00 ug/L 0.00
System Monitoring Compounds 37) 2,4-DDD (SURR) 27.35 235 24707 0.50 ug/L 0.00 Spiked Amount 5.000 Recovery = 10-. 00%
Target Compounds 17.5 Qvalue 2) N-nitroso-dimethyl amine 3.48 74 1334269 ---- 23.48 ug/L 87 3) bis(2-chloroethyl) ether 8.91 93 1954467 23.62 ug/L 99 4) 1,3 - Dichlorobenze 9.30 146 1732311 23.13 ug/L 99 5) 1,4 - Dichlorobenzene 9.51 146 1692917 23.12 ug/L 99 6) 1,2 - Dichlorobenzene 9.88 146 1576053 23.14 ug/L 99 7) 2,2 ' - oxybis (1-Chloropr 10.35 45 2953283 23.11 ug/L 98 8) N-Nitroso-di-n-propylamine 10.70 70 1524469 24.19 ug/L 95 9) Hexachloroethane 10.78 117 . 696185 24.75 ug/L 96 11) Nitrobenzene 11.03 77 2273481 22.73 ug/L 98 12) Isophorone 11.75 82 4012669 22.22 ug/L 98 13) bis(2-Chloroethoxy) methan 12.49 93 2532097 23.13 ug/L 98 14) 1,2,4-Trichlorobenzene 12.82 180 1240899 22.82 ug/L 100 15) Naphthalene 13.00 128 5047870 23.28 ug/L 99 16) Hexachlorobutadiene 13.45 225 612013 22.75 ug/L 97 18) Hexachlorocyclopentadiene 15.52 237 425468 23.55 ug/L 100 19) 2-chloronaphthalene 16.43 162 2679811 23.11 ug/L 97 20) Dimethylphthalate 17.53 163 3084514 22.84 ug/L 99 21) 2,6-Dinitrotoluene 17.64 165 664997 23.29 ug/L 98 22) Acenaphthylene 17.62 152 3803978 23.87 ug/L 99 23) Acenaphthene 18.15 153 2617469 23.20 ug/L 100 24) 2,4-Dinitrotoluene 18.79 165 908140 23.11 ug/L 90 25) Diethylphthalate 19.68 149 2682438 23.54 ug/L 98 26) 4-Chlorophenyl-phenyl ethe 19.82 204 1357180 23.07 ug/L 99 27) Fluorene 19.68 166 2987977 23.25 ug/L 99 28) Azobenzen/ 1,2-Diphenylhyd 20.28 77 4663854 23.00 ug/L 94 30) N-Nitrosodiphenylamine 20.20 169 1994643 22.94 ug/L 98 31) 4.-Bromophenyl-phenyl ether 21.24 248 672316 22.70 ug/L 94 32) Hexachlorobenzene 21.27 284 639388 22.44 ug/L 88 33) Phenanthrene 22.49 178 4134984 22.63 ug/L 99 34) Anthracene 22.63 178 4047238 22.77 ug/L 99 35) Di-n-butylphthalate 24.58 149 4840025 23.40 ug/L 99 36) Fluoranthene 25.99 202 4399032 23.09 ug/L 88 39) Pyrene 26.62 202 4485315 22.12 ug/L 89 40) Butylbenzylphthalate 28.98 149 2016842 22.95 ug/L 86 41) Benzo (a) antracene 30.21 228 3080567 22.16 ug/L 100 42) Bis (2-ethylhexyl) phthala 30.85 149 2594930 22.93 ug/L 98 43) Chrysene 30.32 228 3021313 22.69 ug/L 100 45) Di-n-Octylphthalate 32.70 149 4098361 21.02 ug/L 99 46) Benzo (b) fluoranthene 33.17 252 2344755 21.32 ug/L 94
(#) = qualifier out of range (m) = manual integration C25A0405.D 5080402.M Mon Apr 08 05:17:02 2002 Page 1
NYC-WTC_000060121
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000060576
DEP laboratory report of GCMS calibration analysis for sample AE06800 conducted on April 10, 2002.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000060340
Laboratory report showing GC/MS calibration verification for Method 508 compounds with measured values.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000060909
GCMS calibration verification report for sample AE07173 showing response factors for organic compounds.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000060999
Calibration data for gas chromatography mass spectrometry listing response factors for multiple organic analytes.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000060789
GCMS calibration verification report for sample AE06580 showing response factors for organic compounds.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000059981
Detailed laboratory report listing quantitative concentrations of organic compounds detected in sample AE06090.
1 shared topics · Same agency, volume and box · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000060127
Laboratory report showing GCMS reference standard analysis for sample AE06049 conducted on April 5, 2002.
1 shared topics · Same agency, volume and box · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000061009
Reference standard analysis report for gas chromatography mass spectrometry quantifying recovery of target compounds.
1 shared topics · Same agency, volume and box · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000060796
GCMS reference standard analysis report for sample AE06580 showing response factors and detection limits.
1 shared topics · Same agency, volume and box · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000059990
Detailed laboratory report listing quantitative concentrations of organic compounds detected in sample AE06090.
1 shared topics · Same agency, volume and box · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000039909
Laboratory report providing GCMS reference data for sample AE06760 analyzed in April 2002.
1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000039773
Quantitative results for volatile organic compounds in sample AE06585 analyzed on April 15, 2002.
1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000060103
Environmental Protection Department record from the World Trade Center site containing a redacted name.
Filed in the same folder
NYC-WTC_000060104
Fragmented page from a GCMS record series dated April 6, 2002, likely part of environmental testing documentation.
Filed in the same folder
NYC-WTC_000060109
Mass spectrometer calibration log using DFTPP standard to verify instrument performance on April 5, 2002.
Filed in the same folder
NYC-WTC_000060111
Laboratory report showing GCMS blank test results for sample AE06049 conducted on April 5, 2002.
Filed in the same folder
NYC-WTC_000060127
Laboratory report showing GCMS reference standard analysis for sample AE06049 conducted on April 5, 2002.
Filed in the same folder