GCMS quantitative analysis results for sample AE06090, April 2002

Machine-extracted title · confidence 95%

Detailed laboratory report listing quantitative concentrations of organic compounds detected in sample AE06090.

NYC-WTC_000059990–000059997

Folder label: “GCMS X 3/15/02 A 4/5/02

Page image
Scanned page image, NYC-WTC_000059992
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document Quantitation Report (Not Reviewed)

Data File C:\MSDCHEM\1\DATA\ 04 04 O2B\RFJ14 04.D Vial: .11 Acq On 5 Apr 2002. 2:50 am Operator: Bohlk Sample REFl .3/15/02 Inst Instrumen Mise Multiplr: 1.00 MS Integration Params: BENZO.P Quant Time: Apr 05 06:38:08 2002 Quant Results File: 5080402.RES

Quant Method : C:\MSDCHEM\l\5973N\5080402.M (RTE Integrator) Title : Quantitation For Method 508gcscan Last Update : Fri Apr 05 05:56:22 2002 Response via : Initial Calibration DataAcq Meth : 508SCAN

Internal Standards R.T. Qlon Response Cone Units Dev(Min)

1) 1,4-Dichlorobenzene-d4 9.46 152 1137272 20.00 ug/L -0.01 10) Naphthalene-d8 12.94 136 5147752 20.00 ug/L 0.00 17) Acenaphthene-dlO 18.05 164 2917329 20.00 ug/L 0.00 29) Phenanthrene-dlO 22.42 188 4207548 20.00 ug/L 0.00 38) Chrysene-dl2 30.24 240 3355265 20.00 ug/L 0.00 44) Perylene-dl2 34.12, 264 2141814 20.00 ug/L 0.00

System Monitoring Compounds 37) 2,4-DDD (SURR) 27.35 235 227719 5.45 ug/L 0.00 Spiked Amount 5.000 . Recovery = 109.00%

.Target Compounds Qvalue 2) N-nitroso-dimethyl amine 3.52 74 210946 4.86 ug/L 89 3) bis(2-chloroethyl) ether 8.90 93 709362 11.22 ug/L 82 4) 1,3 - Dichlorobenze 9.29 146 340382 5.95 ug/L ' 99 5) 1,4 - Dichlorobenzene 9.50 146 380370 6.80 ug/L 99 6) 1,2 - Dichlorobenzene 9.88 146 358755 6.90 ug/L 100 7) .2,2 ' - oxybis (1-Chloropr 10.35 45 1160800 11.89 ug/L 94 8) N-Nitroso-di-n-propylamine 10.67 70 577803 12.00 ug/L 90 9) Hexachloroethane 10.77 117 99324 4.62 ug/L 93 11) Nitrobenzene 11.02 77 656161 8.01 ug/L 95 12) Isophorone 11.73 82 1566875 10.59 ug/L 97 13) bis(2-Chloroethoxy) methan 12.47 93 933442 10.41 ug/L 99 14) 1,2,4-Trichlorobenzene 12.82 180 323935 7.27 ug/L 99 15) Naphthalene 12.99 128 1767509 9.95 ug/L 100 16) Hexachlorobutadiene ■ 13.44 225 64113 2.91 ug/L 91 18) Hexachlorocyclopentadiene 15.52 237 9548 0.61 ug/L 89 19) 2-chloronaphthalene 16.42 162 .. 838575 8.33 ug/L 99 20) Dimethylphthalate 17.52 163 1306500 11.14 ug/L 100 21) 2,6-Dinitrotoluene 17.62 165 221568 8.94 ug/L 98 22) Acenaphthylene 17.60 152 1437785 10.40 ug/L 98 23) Acenaphthene 18.14 153 1038025 10.60 ug/L 99 24) 2,4-Dinitrotoluene 18.77 165 258853 7.59 ug/L 99 25) Diethylphthalate 19.64 149 1244757 12.58 ug/L 99 26). 4-Chlorophenyl-phenyl ethe 19.81 204 530365 10.39 ug/L 98 27) Fluorene 19.67 166 1291345 11.58 ug/L 99 28) Azobenzen/ 1,2-Diphenylhyd 20.26 77 1858366 10.56 ug/L 93 30) N-Nitrosodiphenylamine 20.18 169 710291 9.62 ug/L 98 31) 4-Bromophenyl-phenyl ether 21.23 248 259866 10.33 ug/L 88 •32) Hexachlorobenzene 21.26 284 228236 9.43 ug/L 83 33) Phenanthrene 22.47 178 1796263 11.58 ug/L 99 34) Anthracene 22.62 178 1594463 10.56 ug/L 99 35) Di-n-butylphthalate 24.57 149 2148360 12.23 ug/L 100 36) Fluoranthene 25.98 202 1821062. 11.26 ug/L 83 39) Pyrene 26.61 202 1973583 10.07 ug/L 84 40) Butylbenzylphthalate 28.98 149 829385 9.76 ug/L 83 41) Benzo (a) antracene 30.20 228 1417267 10.55 ug/L 100 42) Bis (2-ethylhexyl) phthala 30.85 149 1220778 11.16 ug/L 99 43) Chrysene 30.30 228 1465469 11.38 ug/L 98 45) Di-n-Octylphthalate 32.70 149 1693071 8.25 ug/L 96 46) Benzo (b) fluoranthene 33.16 252. 1142852 9.87 ug/L 93

{#) = qualifier out of range (m) = manual integration RFJ1404.D 5080402.M Fri Apr 05 06:38:59 2002 Page 1

NYC-WTC_000059992

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000059992Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →