NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 28/GCMS X 1/24/02 A 2/26/02
Document / 5 pages

GCMS reference results for sample AE01641, Mar 2002

Machine-extracted title · confidence 90%

Reference data from GCMS analysis of sample AE01641 listing detected compounds and their concentrations in micrograms.

NYC-WTC_000052430–000052434

Folder label: “GCMS X 1/24/02 A 2/26/02

Page image
Scanned page image, NYC-WTC_000052432
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Quantitation Report (QT Reviewed)

Data File : C:\MSDCHEM\l\DATA\022602\0124REF.D Vial: 3 ’ Acq On : 26 Feb 2002 11:40 am Operator: McLean Sample : 1/24 Inst : Instrumen Mise : Multiplr: 1.00 MS Integration Params: BENZO.P Quant Time: Feb 28 11:21:12 2002 Quant Results File: 5080202.RES

Quant Method : C:\MSDCHEM\l\5973N\5080202.M (RTE Integrator) Title : Quantitation For Method 508gcscan Last Update : Mon Feb 25 19:17:14 2002 Response via : Initial Calibration DataAcq Meth : 508SCAN

Internal Standards R.T. Qlon Response Cone Units Dev(Min)

1) 1,4-Dichlorobenzene-d4 9.58 150 1313577 20.00 ug/L 0.00 10) Naphthalene-d8 13.05 136 3410277 20.00 ug/L 0.00 17) Acenaphthene-diO 18.17 164 1873024 20.00 ug/L 0.00 29) Phenanthrene-dlO 22.53 188 2897447 20.00 ug/L 0.00 38) Chrysene-dl2 30.35 240 2762099 20.00 ug/L 0.00 44) Perylene-dl2 34.22 264 1894537 20.00 ug/L 0.00

System Monitoring Compounds 37) 2,4-ddd surr 27.47 235 157794 3.43 ug/L 0.00 Spiked Amount 5.000 Recovery = 68.60%

Target Compounds Qvalue 2) N-nitroso-dimethyl amine 3.66 74 35949m 0.90 ug/L o 3) bis(2-chloroethyl) ether 9.01 93 156242 // 2.51 ug/L 80 4) 1,3 - Dichlorobenze 9.41 146 111781 / 1.90 ug/L 99 5) 1,4 - Dichlorobenzene 9.62 146 118002 /2.02 ug/L 97 6) 1,2 - Dichlorobenzene 10.00 146 116478 _J. 16 ug/L 7) 2,2 ' - oxybis (l-Chloropr 10.46 45 367556 /2.44 ug/L " 97-- y6 8) N-Nitroso-di-n-propylamine 10.78 70 120325 02.52 ug/L 99 9) Hexachloroethane 10.89 117 33359 ,1.41 ug/L 90 . 11) Nitrobenzene 11.13 77 152586 p 1.92 ug/L 96 s C 12) Isophorone 11.85 82 340471 7 2.35 ug/L 98—0 13) bis(2-Chloroethoxy) methan 12.58 93 197786 12.25 ug/L 100 . 14) 1,2,4-Trichlorobenzene 12.94 180 97680 x 2.01 ug/L 94 15) Naphthalene 13.11 128 439619 2.45 ug/L 16) Hexachlorobutadiene 13.56 225 30339 1.13 ug/L 98 — C 18) Hexachlorocyclopentadiene 0.00 237 0 * N.D. 19) 2-chloronaphthalene 16.54 162 217840 02.04 ug/L 98 20) Dimethylphthalate 17.62 163 334205 02.62 ug/L 99 21) 2,6-Dinitrotoluene 17.72 165 50965 01.96 ug/L 91 22) Acenaphthylene 17.72 152 378255 02.57 ug/L 100 23) Acenaphthene 18.25 153 269490 02.64 ug/L 98 24) 2,4-Dinitrotoluene 18.88 165 61239 01.64 ug/L 92 25) Diethylphthalate 19.75 149 314114 02.87 ug/L 98 26) 4-Chlorophenyl-phenyl ethe 19.93 204 149710 02.63 ug/L 98 27) Fluorene 19.78 166 337138 D2.89 ug/L 99 28) Azobenzen/ 1,2-Diphenylhyd 20.37 77 391850 02.35 ug/L 95 30) N-Nitrosodiphenylamine 20.29 169 189480 x 2.45 ug/L 99 31) 4-Bromophenyl-phenyl ether 21.35 248 84552 02.76 ug/L 92 32) Hexachlorobenzene 21.37 284 91600 02.91 ug/L 96 33) Phenanthrene 22.59 178 486255 02.89 ug/L 98 34) Anthracene 22.73 178 426729 02.65 ug/L 99 35) Di-n-butylphthalate 24.68 149 564196 —2.91 ug/L 98 36) Fluoranthene 26.09 202 543119 —2.81 ug/L 97 39) Pyrene 26.71 202 576508 2.57 ug/L 99 _ O 40) Butylbenzylphthalate 29.08 149 185901 31.93 ug/L 96 41) Benzo (a) antracene 30.31 228 452402 / 2.50 ug/L 99 -O 42) Bis (2-ethylhexyl) phthala 30.95 149 278421 ___ 2-. 22 ug/L 98 43) Chrysene 30.40 228 509453 02.88 ug/L 98 — 45) Di-n-Octylphthalate 32.79 149 353866 £1.82 ug/L 99 46) Benzo (b) fluoranthene 33.26 252 3 8 9 8 81 ,2.46 ug/L 99

(#) = qualifier out of range (m) = manual integration 0124REF.D 5080202.M Thu Feb 28 11:21:33 2002 Page 1

NYC-WTC_000052432

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000052432Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →