NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 14/GCMS X 2/4/02 A 2/27/02
Document / 4 pages

GCMS reference standard results for sample AE02457, March 2002

Machine-extracted title · confidence 100%

Laboratory report presenting quantitative results for reference standards used to validate the analysis of sample AE02457 on March 1, 2002.

NYC-WTC_000010689–000010692

Folder label: “GCMS X 2/4/02 A 2/27/02

Page image
Scanned page image, NYC-WTC_000010691
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Quantitation Report (QT Reviewed)

• Data File : C:\MSDCHEM\1\DATA\022702\0204REF.D Vial: 3 Acq On : 27 Feb 2002 10:42 am Operator: McLean Sample : GC SCAN 2/4 Inst : Instrumen Mise : Multiplr: 1.00 MS Integration Params: BENZO.P Quant Time: Mar 01 08:49:24 2002 Quant Results File: 5080202.RES

Quant Method : C:\MSDCHEM\l\5973N\5080202.M (RTE Integrator) Title : Quantitation For Method 508gcscan Last Update : Mon Feb 25 19:17:14 2002 Response via : Initial Calibration DataAcq Meth : 508SCAN

Internal Standards R.T. Qlon Response Cone Units Dev(Min)

1) 1,4-Dichlorobenzene-d4 9.58 150 1698715 20.00 ug/L 0.00 10) Naphthalene-d8 13.06 136 4359925 20.00 ug/L 0.00 17) Acenaphthene-dl0 18.17 164 2371851 20.00 ug/L 0.00 29) Phenanthrene-diO 22.53 188 3633859 20.00 ug/L 0.00 38) Chrysene-dl2 30.35 240 3519560 20.00 ug/L 0.00 44) Perylene-dl2 34.23 264 2458657 20.00 ug/L 0.00

System Monitoring Compounds 37) 2,4-ddd surr 27.47 235 191118 3.31 ug/L 0.00 Spiked Amount 5.000 Recovery = 66.20%

Target Compounds Qvalue 2) N-nitroso-dimethyl amine 3.66 74 58424 11.14 ug/L 100 3) bis(2-chloroethyl) ether 9.01 93 202886 12.52 ug/L 81 4) 1,3 - Dichlorobenze 9.41 146 70255 /0.93 ug/L 94 5) 1,4 - Dichlorobenzene 9.62 146 84232 11.12 ug/L 97 6) 1,2 - Dichlorobenzene 10.00 146 91740 1.31 ug/L 92 7) 2,2 ’ - oxybis (l-Chloropr 10.46 45 482338 12.48 ug/L 99 8) N-Nitroso-di-n-propylamine 10.78 70 144121 12.34 ug/L 94 9) Hexachloroethane 10.89 117 13101 0.43 ug/L 100 11) Nitrobenzene 11.13 77 196480 (1.93 ug/L 99 12) 1sophorone 11.85 82 409140 ./2.21 ug/L 96 13) bis(2-Chloroethoxy) methan 12.58 93 254792 *2.27 ug/L 99 14) 1,2,4-Trichlorobenzene 12.94 180 82176 *1.33 ug/L 97 15) Naphthalene 13.11 128 507732 12.21 ug/L 99 16) Hexachlorobutadiene 13.56 225 10446 0.30 ug/L 89 18) Hexachlorocyclopentadiene 15.64 237 1118m 6 0.05 ug/L 19) 2-chloronaphthalene 16.54 162 272170 C2.01 ug/L 96 20) Dimethylphthalate 17.62 163 420371 12.60 ug/L 100 21) 2,6-Dinitrotoluene 17.72 165 62151 1.88 ug/L 93 22) Acenaphthylene 17.72 152 476237 1/2.56 ug/L 99 2 3) Acenaphthene 18.25 153 336997 2.60 ug/L 98 24) 2,4-Dinitrotoluene 18.88 165 73705 ✓ 1.56 ug/L 94 25) Diethylphthalate 19.75 149 409000 2.95 ug/L 99 26) 4-Chlorophenyl-phenyl ethe 19.93 204 186950 12.60 ug/L 97 27) Fluorene 19.78 166 426210 12.89 ug/L 100 28) Azobenzen/ 1,2-Diphenylhyd 20.37 77 501489 02.37 ug/L 98 30) N-Nitrosodiphenylamine 20.29 169 250089 1/2.58 ug/L 96 31) 4-Bromophenyl-phenyl ether 21.35 248 106837 2.78 ug/L 95 32) Hexachlorobenzene 21.37 284 98172 2.49 ug/L 98 33) Phenanthrene 22.59 178 618130 2.93 ug/L 100 34) Anthracene 22.74 178 550708 2.72 ug/L 99 35) Di-n-butylphthalate 24.68 149 690400 2.84 ug/L 99 36) Fluoranthene 26.09 202 692399 2.86 ug/L 98 39) Pyrene 26.71 202 748118 .2.62 ug/L 98 40) Butylbenzylphthalate 29.08 149 259641 2.12 ug/L 95 41) Benzo (a) antracene 30.31 228 626758 2.71 ug/L 99 42) Bis (2-ethylhexyl) phthala 30.95 149 548471 3.44 ug/L 97 43) Chrysene 30.41 228 664615 2.95 ug/L 99 45) Di-n-Octylphthalate 32.79 149 567205 2.25 ug/L 100 46) Benzo (b) fluoranthene 33.26 252 554606 12.70 ug/L 98

(#) = qualifier out of range (m) = manual integration 0204REF.D 5080202.M Fri Mar 01 08:50:03 2002 Page 1

NYC-WTC_000010691

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000010691Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →