NYC 9/11 Public Portal Document
Data File : C:\MSDCHEM\1\5973N\O2 JAN15\00559.D Vial: 3
Acq On : 15 Jan 2002 3:10 pm Operator:
Sample : 508 scan Inst : Instrumen
Mise : January 15, 2002 Multiplr: 1.00
MS Integration Params: SPLIT.P
Quant Time: Jan 15 15:51:54 2002 Quant Results File: SCAN508.RES
Quant Method : C:\MSDCHEM\1...\SCAN508.M (RTE Integrator)
Title : 508 scan method
Last Update : Fri Jan 11 13:20:07 2002
Response via : Initial Calibration
DataAcq Meth : SCAN508
Internal Standards R.T. Qlon Response Cone Units Dev(Min)
1) 1,4-Dichlorobenzene-d4 9.72 152 1086407 20.00 ug/L 0.00
10) Naphthalene-d8 13.19 136 4633011 20.00 ug/L -0.02
17) Acenaphthene-dlO 18.34 164 2379772 20.00 ug/L -0.01
29) Phenanthrene-dlO 22.63 188 3995310 20.00 ug/L -0.03
38) Chrysene-dl2 30.49 240 3551639 20.00 ug/L -0.02
44) Perylene-dl2 34.42 264 2531129 20.00 ug/L 0.00
System Monitoring Compounds
37) 2,4-DDD 27.73 235 314277 4.98 ug/L 0.00
Spiked Amount 5.000 Recovery = 99.60%
Target Compounds 95100/0.21 ug/L Qvalue
2) n-Nitrosodimethylamine 3.60 74 12
20) Dimethylphthalate 18.34 163 381806 ' 2.43 ug/L 56
21) 2,6-Dinitrotoluene 18.34 165 299891 ,9.78 ug/L 17
25) Diethylphthalate 20.00 149 19563 0.13 ug/L 98
33) Phenanthrene 22.69 178 10495 / 0.05 ug/L 97
34) Anthracene 22.69 178 10495 /■ 0.05 ug/L 97
35) Di-n-butylphthalate
36) Fluoranthene
24.85
26.22
149
202
93209
21050
1 0.36 ug/L
0.10 ug/L
95
91
3 9) Pyrene 26.85 202 22490 . 3 0.08 ug/L 94
40) Butylbenzylphthalate 29.24 149 7958. 1 0.06 ug/L 97
41) Benzo(a)anthracene 30.47 228 33533 AR 0.16 ug/L 97
42) Bis(2-ethylhexyl)phthalate 31.11 149 42323 V 0.79 ug/L 94
43) Chrysene 30.56 228 38785 \ 0.19 ug/L 94
45) Di-n-octylphthalate 32.82 149 5494 \ 0.02 ug/L # 74
46) Benzo(b)fluoranthene 33.50 252 9127 0.05 ug/L 93
47) Benzo(k)fluoranthene 33.50 252 9127 0.05 ug/L 92
48) Benzo(a)pyrene 34.42 252 18019 011 ug/L # 1
51) Benzo(g,h,i)perylene 37.70 276 5194 0.04 ug/L 4 49
(#) = qualifier out of range (m) = manual integration
00559.D SCAN508.M Tue Jan 15 15:51:55 2002 Page 1
NYC-WTC_000051729
OCR can misread numbers and units. Confirm readings against the page image before using them.