NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 27/GCMS X 4/8/02 A 4/17/02
Document / 12 pages

GCMS blank analysis results for sample AE08251, April 2002

Machine-extracted title · confidence 100%

Laboratory report of a GCMS blank analysis for sample AE08251 conducted on April 17, 2002, showing non-detect levels for various compounds.

NYC-WTC_000047757–000047768

Folder label: “GCMS X 4/8/02 A 4/17/02

Page image
Scanned page image, NYC-WTC_000047758
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Quantitation Report (QT Reviewed)

Data File : C:\MSDCHEM\l\DATA\020417\0408LB.D Vial: 3 Acq On : 17 Apr 2002 11:01 am Operator: Nefliu Sample : 04/08 1b Inst Instrumen Mise : Multiplr: 1.00 MS Integration Params: EVENTS.E Quant Time: Apr 17 11:42:27 2002 Quant Results File: 04 1702SCAN . RE

Quant Method : C:\MSDCHEM\1\METHODS\041702SCAN.M (Chemstation Integrator) Title : 508 Modified GC/MS scan Last Update : Wed Apr 17 08:01:11 2002 Response via : Initial Calibration DataAcq Meth : 508SCAN

Internal Standards R.T. Qlon Response Cone Units Dev(Min)

1) 1,4-Dichlorobenzene-d4 9.99 152 6365161 40.00 ug/L -0.02 10) Napthalene-d8 13.49 136 24571066 40.00 ug/L -0.03 17) Acenapthalene-dlO 18.63 164 13131818 40.00 ug/L -0.02 29) Phenanthranene-dlO 23.02 188 19740264 40.00 ug/L -0.02 37) Chrysene-dl2 30.88 240 13925329 40.00 ug/L -0.05 43) Perylene-dl2 34.79 264 9384085 40.00 ug/L -0.02

System Monitoring Compounds 2 7) TCMX 20.60 207 364152 5.00 ug/L 0.00 Spiked Amount 8.000 Recovery = 62.50%

Target Compounds Qvalue

(#) = qualifier out of range (m) = manual integration (+) = signals summed 0408LB.D 041702SCAN.M Thu Apr 18 14:05:43 2002 Page 1

NYC-WTC_000047758

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000047758Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →