NYC-WTC_000035497
GCMS scan results for sample AD28858 dated December 16, 2001, showing no unusual compounds found.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗Lab notes for sample AD28860 indicate no unusual compounds detected but recovery was below acceptance range.
NYC-WTC_000035765–000035772Folder label: “GCMS X 11/28/01 A 12/7/01”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Quantitation Report (QT Reviewed)
Data File C:\HPCHEM\l\DATA\DEC0701\28860.D Vial: 6 - Acq On 7 Dec 2001 7:49 pm Operator: 209 GALOS Sample 11/28 gc/ms scan Inst : GC/MS 209 Mise Multiplr: 1.00 MS Integration Params: RTEINT.P Quant Time: Dec 11 15:46 2001 Quant Results File: GCMS1126.RES
Quant Method : C:\HPCHEM\1\METHODS\GCMS1126.M (RTE Integrator) Title : 209 625/TCLP calibration table Last Update : Wed Nov 28 15:06:24 2001 Response via : Initial Calibration DataAcq Meth : GCMS1126
Internal Standards R.T. Qlon Response Cone Units Dev(Min)
1) 1,4-Dichlorobenzene-d4 11.67 152 1029753 20.00 ug/1 -0.03 10) Naphthalene-d8 15.28 136 3919522 20.00 ug/1 -0.03 17) Acenaphthene-dl0 20.56 164 1943065 20.00 ug/1 -0.02 29) Phenanthrene-diO 24.97 188 2837849 20.00 ug/1 -0.02 38) Chrysene-dl2 33.02 240 1896857 20.00 ug/1 -0.02 44) Perylene-dl2 37.10 264 1314976 20.00 ug/1 -0.02
System Monitoring Compounds 37) 2,4-DDD 30.05 235 76763 2.27 ug/mL -0.02 Spiked Amount 5.000 Recovery = 45.40%
Target Compounds Qvalue 2) N-nitroso-dimethyl amine 5.14 74 316 N.D. 3) bis(2-Chloroethyl)ether 0.00 93 0 N.D. 4) 1,3-Dichlorobenzene 0.00 146 0 N.D. 5) 1,4-Dichlorobenzene 0.00 146 0 N.D. 6) 1,2-Dichlorobenzene 0.00 146 0 N.D. 7) 2,2’-oxybis(1-Chioropropan 0.00 45 0 N.D. 8) N-Nitroso-di-n-propylamine 0.00 70 0 N.D. 9) Hexachloroethane 0.00 117 0 N.D. 11) Nitrobenzene 13.36 77 103 N.D. 12) 1sophorone 0.00 82 0 N.D. 13) bis(2-Chloroethoxy)methane 0.00 93 0 N.D. 14) 1,2,4-Trichlorobenzene 0.00 180 0 N.D. 15) Naphthalene 15.33 128 1017 N.D. 16) Hexachlorobutadiene 0.00 225 0 N.D. 18) Hexachlorocyclopentadiene 0.00 237 0 N.D. 19) 2-Chloronaphthalene 0.00 162 0 N.D. 20) Dimethylphthalate 0.00 163 0 N.D. 21) 2,6-Dinitrotoluene 0.00 165 0 N.D. d 22) Acenaphthylene 0.00 152 0 N.D. 23) Acenaphthene 20.56 153 143 N.D. 24) 2,4-Dinitrotoluene 21.13 165 232 N.D. 25) Diethylphthalate 0.00 149 0 N.D. 26) 4-Chlorophenyl-phenylether 0.00 204 0 N.D. 27) Fluorene 0.00 166 0 N.D. 28) Azobenzen/ 1,2-Diphenylhyd 0.00 77 0 N.D.
(#) = qualifier out of range (m) = manual integration 28860.D GCMS1126.M Wed Dec 12 10:56:01 2001 Page 1
NYC-WTC_000035767
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000035497
GCMS scan results for sample AD28858 dated December 16, 2001, showing no unusual compounds found.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035290
Laboratory report confirming no unusual compounds were detected in the analyzed environmental sample.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035298
Laboratory report confirming no unusual compounds were detected in the analyzed environmental sample.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035274
Laboratory report confirming no unusual compounds were detected in the analyzed environmental sample.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035266
Laboratory report confirming no unusual compounds were detected in the analyzed environmental sample.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035249
Laboratory report confirming no unusual compounds were detected in the analyzed environmental sample.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035322
Laboratory report noting detection of Di-n-butylphthalate in a WTC environmental sample.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035444
GCMS scan results for sample AD28800 dated December 16, 2001, showing no unusual compounds found.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035330
Laboratory report noting detection of Di-n-butylphthalate in a WTC environmental sample.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035282
Laboratory report noting detection of bis(2-Ethylhexyl)phthalate in a WTC environmental sample.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035489
GCMS scan results for sample AD28857 dated December 16, 2001, detecting bis(2-Ethylhexyl)phthalate and noting low pH.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035481
GCMS scan results for sample AD28856 dated December 16, 2001, detecting bis(2-Ethylhexyl)phthalate.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000035755
Lab report noting bis(2-Ethylhexyl) Sebacate detection and potential laboratory contamination in a water sample.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000036289
Laboratory analysis report for sample AD29455 conducted on December 28, 2001, including surrogate recovery data.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035618
Lab report noting bis(2-Ethylhexyl)phthalate detection and recovery issues in a water sample.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000036403
Laboratory report documenting GCMS analysis of sample AD29299 conducted on January 4, 2002, showing unknown compounds and surrogates.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035640
Lab report noting bis(2-Ethylhexyl)phthalate detection, recovery issues, and low pH.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035589
Lab report noting bis(2-Ethylhexyl)phthalate detection and recovery issues in a water sample.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000035662
Department of Environmental Protection record logging GCMS X samples from November to December 2001.
Filed in the same folder
NYC-WTC_000035663
Fragmented document containing method 508 data and sample IDs processed by GCMS in late 2001.
Filed in the same folder
NYC-WTC_000035664
Laboratory data sheet recording GCMS Method 508 analysis of a blank sample for nitrosamines and chlorinated compounds.
Filed in the same folder
NYC-WTC_000035674
Calibration data sheet verifying instrument response for nitrosamines and benzene derivatives.
Filed in the same folder
NYC-WTC_000035678
Document containing calculated reference values for various organic compounds analyzed by GCMS.
Filed in the same folder