NYC-WTC_000034971
Blank test results confirming no detectable contaminants above method detection limits for sample AD28662.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗Laboratory report documenting GCMS analysis of sample AD28471 conducted on December 6, 2001.
NYC-WTC_000034347–000034365Folder label: “GCMS X 11/21/01 A 11/27 - 11/28/01”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Library Search Compound Report Data File C:\HPCHEM\l\DATA\DEC0401\28471.D vial: 7 Acq On 4 Dec 2001 6:13 pm Operator: 209 GALOS Sample gc/ms 11/24 Inst : GC/MS 209 Mise Multiplr: 1.00 MS integration Params: LSCINT.P Quant Method : C:\HPCHEM\1\METHODS\GCMS1126.M (RTE Integrator) Tit ..e : 209 625/TCLP calibration table Libary : C : DATABASE\NBS75K . L ***** • *************** ************************************************* Peak umber 8 Hexadecane Concentration Rank 4 R.T EstConc Area Relative to ISTD R.T. 33.6. 1.26 ug/1 331071 Chrysene-dl2 33.04 Hit# of 5 Tentative ID MW MolForm CAS#
1 Headecane 226 C16H34 000544-76-3 2 He tacosane 380 C27H56 000593-49-7 91 3 Tetracosane 338 C24H50 000646-31-1 90 4 Ti cosane 324 C23H48 000638-67-5 87 Abundanct Scan 3112 (33.615 mtn): 28471 .D (-) m/z 57.00 100.00% 57
5000 85
41| || d I 11113 1 33.20 33.40 33.60 33.80 34.00 141 168 ,197 , 226.............. 281 309 * "t .T i__ , , II"TT 11’ ill. It J . m/z 71.00 71.06% m/z-> 40 60 80 100 120 14J 160 180 200 220 240 260 280 300 320 340 360 380 Abundan. #29267: Hexadecane 57 i
5000 85 T TOTTTTer 33.20 33.40 33.60 33.80 34.00 m/z 43.05 69.23% I 113 .
miz-> 40 60 417141 7—80 100 196 226 TTTTT’TT I.... I 120 140 160 180 200 220 240 260 280 300 320 340 360 380 r ‘111 ||M . | 1
Abundance #52248: Heptacosane 57 T"T --P T TT 33.20 33,40 33.60 33.80 34.00 500.. 85 m/z 85.00 49.01%
t y । j 113 141 , 169 196 224 281 324 380 - —II —Tr TTIUIUTTT—u mz-> 40 6° 80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 Abundanc. #73543: Tetracosane —= 1 — — - 57 33.20 33.40 33.60 33.80 34.00 m/z 41.05 26.47% 5000 | 1 85 : i
113 155 183 294 338 ‘ I ' > ilt < । n। “IpT , 111111111. ' i'" ' i " " I' " ' I''" i " TTTPAT m/z-> 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 33.20 33.40 33.60 33.80 34.00
28471.D GCMS1126.M Wed DeC 05 11:27:45 2001 Page 8
NYC-WTC_000034361
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000034971
Blank test results confirming no detectable contaminants above method detection limits for sample AD28662.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035072
Laboratory report noting TurboVap contamination and low recovery rate for sample AD28678.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000034311
Laboratory report documenting GCMS analysis of sample AD28430 conducted on December 6, 2001.
1 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035089
Laboratory report noting TurboVap contamination with recovery data for sample AD28693.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035135
Laboratory report noting di-n-butylphthalate detection and low pH with recovery data for sample AD28694.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035153
Laboratory report noting TurboVap contamination and recovery data for sample AD28663.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035195
Laboratory report noting low pH and TurboVap contamination with recovery data for sample AD28689.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035008
Laboratory report detailing GCMS scan results for sample AD28669, noting phthalate detection and recovery rates.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035052
Laboratory report noting low pH and TurboVap contamination with recovery data for sample AD28691.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035115
Laboratory report noting TurboVap contamination and recovery data for sample AD28664.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035026
Laboratory report noting di-n-butylphthalate detection and TurboVap contamination with recovery data for sample AD28688.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000088346
Laboratory report documenting GC/MS analysis of environmental sample AD23270 conducted on October 15, 2001.
1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000034154
Single page of raw GCMS data or header information from samples tested in late November 2001.
Filed in the same folder
NYC-WTC_000034155
Technical data sheet recording instrument parameters and calibration details for GCMS Method 508 analysis conducted in November 2001.
Filed in the same folder
NYC-WTC_000034156
Instrument sequence log listing calibration standards and sample IDs processed between November 26 and 30, 2001.
Filed in the same folder
NYC-WTC_000034160
Laboratory report of a method blank analysis for sample AD28263 conducted on November 26, 2001.
Filed in the same folder
NYC-WTC_000034168
Laboratory report of GCMS calibration data for sample AD28263 conducted on November 26, 2001.
Filed in the same folder