NYC 9/11 Public Portal Document
Quantitation Report (QT Reviewed)
Data File : C:\HPCHEM\1\DATA\NOV2 601\28326.D Vial: 17
Acq On : 28 Nov 2001 9:54 am Operator: 209 GALOS
Sample : 11/20 scan Inst : GC/MS 209
Mise Multiplr: 1.00
MS Integration Params: GOOFY.P
Quant Time: Dec 31 14:37 2001 Quant Results File: GCMS1126.RES
Quant Method : C:\HPCHEM\l\METH0DS\GCMS1126.M (RTE Integrator)
Title : 209 625/TCLP calibration table
Last Update : Fri Dec 28 15:11:00 2001
Response via : Initial Calibration
DataAcq Meth : NP103001
Internal Standards R.T. Qlon Response Cone Units Dev(Min)
1) 1,4-Dichlorobenzene-d4 11.70 152 1025907 20.00 ug/1 0.00
10) Naphthalene-d8 15.31 136 3862442 20.00 ug/1 0.00
17) Acenaphthene-dlO 20.57 164 1817855 20.00 ug/1 0.00
29) Phenanthrene-diO 24.99 188 2386808 20.00 ug/1 0.00
38) Chrysene-dl2 33.02 240 1069815 20.00 ug/1 -0.01
44) Perylene-dl2 37.12 264 675480 20.00 ug/1 0.00
System Monitoring Compounds
37) 2,4-DDD 30.07 235 105830 4.03 ug/mL 0.00
Spiked Amount 5.000 Recovery = 80.60%
Target Compounds Qvalue
2) N-nitroso-dimethyl amine 0.00 74 0 N.D.
3) bis(2-Chloroethyl)ether 0.00 93 0 N.D.
4) 1,3-Dichlorobenzene 0.00 146 0 N.D.
5) 1,4-Dichlorobenzene 0.00 146 0 N.D.
6) 1,2-Dichlorobenzene 0.00 146 0 N.D.
7) 2,2' -oxybis (1-Chloropropan 0.00 45 0 N.D.
8) N-Nitroso-di-n-propylamine 0.00 70 0 N.D.
9) Hexachloroethane 0.00 117 0 N.D.
11) Nitrobenzene 0.00 77 0 N.D.
12) Isophorone 0.00 82 0 N.D.
13) bis(2-Chloroethoxy)methane 0.00 93 0 N.D.
14) 1,2,4-Trichlorobenzene 0.00 180 0 N.D.
15) Naphthalene 15.36 128 945 / N.D.
16) Hexachlorobutadiene 0.00 225 0 N.D.
18) Hexachlorocyclopentadiene 0.00 237 0 N.D.
19) 2-Chloronaphthalene 0.00 162 0 N.D.
20) Dimethylphthalate 0.00 163 0 N.D.
21) 2,6-Dinitrotoluene 0.00 165 0 N.D.
22) Acenaphthylene 0.00 152 0 N.D.
23) Acenaphthene 0.00 153 0 N.D.
24) 2,4-Dinitrotoluene 21.18 165 273/ N.D.
25) Diethylphthalate 22.08 149 1456 / N.D.
26) 4-Chlorophenyl-phenylether 0.00 204 0 N.D.
27) Fluorene 0.00 166 0 N.D.
28) Azobenzen/ 1,2-Diphenylhyd 0.00 77 0 N.D.
(#) = qualifier out of range (m) = manual integration
28326.D GCMS1126.M Mon Dec 31 14:39:09 2001 Page 1
NYC-WTC_000033947
OCR can misread numbers and units. Confirm readings against the page image before using them.