NYC-WTC_000022953
GCMS calibration table and instrument data for TCLP analysis recorded on May 5-7, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗Calibration table listing response factors for deuterated standards used in TCLP analysis on May 5, 2002.
NYC-WTC_000023195–000023202Folder label: “GCMS X 5/8/02 A 5/9/02”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document LSC Area Percent Report
. Data File C:\HPCHEM\l\DATA\MAY0302\9577.D Vial: 50 Acq On 5 May 2002 4:02 pm Operator: Sample GC/MS SCAN 4/23 Inst : 209 Mise Multiplr: 1.00 MS Integration Params: LSCINT.P
Method : C:\HPCHEM\1\METHODS\GCMS0501.M (RTE Integrator) Title : 209 625/TCLP calibration table Smoothing : OFF Filtering: 5 Sampling : 1 Min Area: 1 % of largest Peak Start Thrs: 0.2 Max Peaks: 100 Stop Thrs : 0 Peak Location: TOP
If leading or trailing edge < 100 prefer < Baseline drop else tangent > Peak separation: 5 Signal : TIC peak R.T. first max last PK peak peak peak % of # min scan scan scan TY height area % max. total
1 8.163 337 341 347 rBV 829917 1664357 46.08% 8.733% 2 12.195 775 781 795 rBV 1126203 2603443 72.09% 13.661% 3 14.798 1059 1065 1070 rBV 149539 288666 7.99% 1.515% 4 15.824 1172 1177 1193 rW 1588849 3258336 90.22% 17.097% 5 21.130 1750 1756 1778 rBV 1744426 3611616 100.00% 18.951% 6 23.274 1982 1990 1998 rBV 74810 150136 4.16% 0.788% 7 25.574 2234 2241 2253 rBV2 1546992 3290093 91.10% 17.264% 8 33.629 3114 3120 3141 rBV2 1008435 2355695 65.23% 12.361% 9 37.862 3573 3582 3605 rBV2 620656 1835207 50.81% 9.630%
Sum of corrected areas: 19057549 9577.D GCMS0501.M Tue May 07 15:01:44 2002
NYC-WTC_000023198
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000022953
GCMS calibration table and instrument data for TCLP analysis recorded on May 5-7, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000023055
GCMS calibration table and instrument data for TCLP analysis recorded on May 5-7, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000022930
GCMS calibration table and instrument data for TCLP analysis recorded on May 5-7, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000023754
Laboratory report of GCMS analysis for sample AE09654 conducted on May 23, 2002, showing surrogate recovery data.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000013146
Calibration table listing response factors for deuterated standards and target compounds used in gas chromatography-mass spectrometry analysis.
1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000046276
Laboratory report showing GCMS calibration data for sample AE09580 generated on May 3-6, 2002.
1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000046313
Laboratory report showing GCMS calibration data for sample AE09586 generated on May 4-6, 2002.
1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000046332
Laboratory report showing GCMS calibration data for sample AE09587 generated on May 4-6, 2002.
1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000045490
Technical document displaying GCMS calibration data and compound retention times for sample AE09448 processed in early May 2002.
1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000013117
Calibration table listing response factors for deuterated standards and target compounds used in gas chromatography-mass spectrometry analysis.
1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000045472
Technical document displaying GCMS calibration data and compound retention times for sample AE09447 processed in early May 2002.
1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000013277
Calibration table listing response factors for deuterated standards and target compounds used in gas chromatography-mass spectrometry analysis.
1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000013146
Calibration table listing response factors for deuterated standards and target compounds used in gas chromatography-mass spectrometry analysis.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000022953
GCMS calibration table and instrument data for TCLP analysis recorded on May 5-7, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000023754
Laboratory report of GCMS analysis for sample AE09654 conducted on May 23, 2002, showing surrogate recovery data.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000023353
Laboratory report showing GC/MS analysis results for sample AE09520 including surrogate recovery data on May 16, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000023701
Laboratory report of GCMS analysis for sample AE10063 conducted on May 23, 2002, showing surrogate recovery data.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000013277
Calibration table listing response factors for deuterated standards and target compounds used in gas chromatography-mass spectrometry analysis.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000022961
Department of Environmental Protection administrative record sheet for World Trade Center site activities dated May 2002.
Filed in the same folder
NYC-WTC_000022962
Fragmentary record containing a document identifier and date from the DEP GCMS analysis series.
Filed in the same folder
NYC-WTC_000022965
Laboratory report of a GCMS blank run conducted on May 14, 2002, showing non-detect results for various compounds.
Filed in the same folder
NYC-WTC_000022990
Laboratory report documenting GCMS calibration verification analysis conducted on May 14, 2002.
Filed in the same folder
NYC-WTC_000022994
Laboratory report of GCMS reference standard analysis conducted on May 14, 2002, showing recovery percentages.
Filed in the same folder