NYC 9/11 Public Portal Document
Quantitation Report (QT Reviewed)
Data, File C:\HPCHEM\1\DATA\DEC3101\30908.D Vial: 47
Acq On 2 Jan 2002 10:28 am Operator: 209 GALOS
Sample gems scan 12/19a Inst : GC/MS 209
Mise Multiplr: 1.00
MS Integration Params: RTEINT.P
Quant Time: Jan 25 9:52 2002 Quant Results File: GCMS1126.RES
Quant Method : C:\HPCHEM\1\METHODS\GCMS1126.M (RTE Integrator)
Title : 209 625/TCLP calibration table
Last Update : Tue Jan 22 11:56:23 2002
Response via : Initial Calibration
DataAcq Meth : GCMS1126
Internal Standards R.T. Qlon Response Cone Units Dev(Min)
1) 1,4-Dichlorobenzene-d4 11.67 152 720876 20.00 ug/1 -0.02
10) Naphthalene-d8 15.28 136 2734061 20.00 ug/1 -0.02
17) Acenaphthene-diO 20.56 164 1382069 20.00 ug/1 -0.02
29) Phenanthrene-diO 24.99 188 2013356 20.00 ug/1 0.00
38) Chrysene-dl2 33.03 240 1230554 20.00 ug/1 0.00
44) Perylene-dl2 37.12 264 685077 20.00 ug/1 0.00
System Monitoring Compounds
37) 2,4-DDD 30.07 235 120420 5.44 ug/mL 0.00
Spiked Amount 5.000 Recovery = 108.80%
Target Compounds Qvalue
2) N-nitroso-dimethyl amine 5.30 74 203 N.D.
3) bis(2-Chloroethyl)ether 0.00 93 0 N.D.
4) 1,3-Dichlorobenzene 0.00 146 0 N.D.
5) 1,4-Dichlorobenzene 0.00 146 0 N.D.
6) 1,2-Dichlorobenzene 0.00 146 0 N.D.
7) 2,2'-oxybi s(1-Chioropropan 0.00 45 0 N.D.
8) N-Nitroso-di-n-propylamine 0.00 70 0 N.D.
9) Hexachloroethane 0.00 117 0 N.D.
11) Nitrobenzene 0.00 77 0 N.D.
12) 1sophorone 0.00 82 0 N.D.
13) bis(2-Chloroethoxy)methane 0.00 93 0 N.D.
14) 1,2,4-Trichlorobenzene 0.00 180 0 N.D.
15) Naphthalene 15.34 128 1041 N.D.
16) Hexachlorobutadiene 0.00 225 0 N.D.
18) Hexachlorocyclopentadiene 0.00 237 0 N.D.
19) 2-Chloronaphthalene 0.00 162 0 N.D.
20) Dimethylphthalate 0.00 163 0 N.D.
21) 2,6-Dinitrotoluene 0.00 165 0 N.D.
2 2) Acenaphthylene 0.00 152 0 N.D.
23) Acenaphthene 0.00 153 0 N.D.
24) 2,4-Dinitrotoluene 21.07 165 205 N.D.
25) Diethylphthalate 0.00 149 0 N.D.
26) 4-Chlorophenyl-phenylether 0.00 204 0 N.D.
27) Fluorene 0.00 166 0 N.D.
28) Azobenzen/ 1,2-Diphenylhyd 0.00 77 0 N.D.
(#) = qualifier out of range (m) = manual integration
30908.D GCMS1126.M Fri Jan 25 09:53:38 2002 Page 1