NYC 9/11 Public Portal Document
Quantitation Report (QT Reviewed)
Data File C:\HPCHEM\1\DATA\DEC3101\30695.D Vial: 32
Acq On 1 Jan 2002 6:59 pm Operator: 209 GALOS
Sample gems scan 12/19 Inst : GC/MS 209
Mise Multiplr: 1.00
MS Integration Params: GOOFY.P
Quant Time: Jan 1 19:48 2002 Quant Results File: GCMS1126.RES
Quant Method : C:\HPCHEM\1\METHODS\GCMS1126.M (RTE Integrator)
Title . : 209 625/TCLP calibration table
Last Update : Fri Dec 28 15:11:00 2001
Response via : Initial Calibration
DataAcq Meth : GCMS1126
Internal Standards R.T. Qlon Response Cone Units Dev(Min)
1) 1,4-Dichlorobenzene-d4 11.68 152 757692 20.00 ug/1 -0.02
10) Naphthalene-d8 15.28 136 2867072 20.00 ug/1 -0.03
17) Acenaphthene-diO 20.56 164 1451584 20.00 ug/1 -0.01
29) Phenanthrene-diO 24.99 188 2111611 20.00 ug/1 0.00
38) Chrysene-dl2 33.02 240 1171060 20.00 ug/1 -0.01
44) Perylene-dl2 37.12 264 627941 20.00 ug/1 0.00
System Monitoring Compounds
37) 2,4-DDD 30.07 235 121314 5.23 ug/mL 0.00
Spiked Amount 5.000 Recovery = 104.60%
Target Compounds Qvalue
2) N-nitroso-dimethyl amine 5.20 74 356 N.D.
3) bis(2-Chloroethyl)ether 0.00 93 0 N.D.
4) 1,3-Dichlorobenzene 0.00 146 0 N.D.
5) 1,4-Dichlorobenzene 0.00 146 0 N.D.
6) 1,2-Dichlorobenzene 0.00 146 0 N.D.
7) 2,2’-oxybis(1-Chloropropan 0.00 45 0 N.D.
8) N-Nitroso-di-n-propylamine 0.00 70 0 N.D.
9) Hexachloroethane 0.00 117 0 N.D.
11) Nitrobenzene 0.00 77 0 N.D.
12) Isophorone 13.88 82 116 N.D.
13) bis(2-Chloroethoxy)methane 0.00 93 0 N.D.
14) 1,2,4-Trichlorobenzene 0.00 180 0 N.D.
15) Naphthalene 15.33 128 344 N.D.
16) Hexachlorobutadiene 0.00 225 0 N.D.
18) Hexachlorocyclopentadiene 0.00 237 0 N.D.
19) 2-Chloronaphthalene 0.00 162 0 N.D.
20) Dimethylphthalate 0.00 163 0 N.D.
21) 2,6-Dinitrotoluene 0.00 165 0 N.D.
22) Acenaphthylene 0.00 152 0 N.D.
2 3) Acenaphthene 0.00 153 0 N.D.
24) 2,4-Dinitrotoluene 21.34 165 213 N.D.
25) Diethylphthalate 22.14 149 1475 N.D.
26) 4-Chlorophenyl-phenylether 0.00 204 0 N.D.
2 7) Fluorene 0.00 166 0 N.D.
28) Azobenzen/ 1,2-Diphenylhyd 0.00 77 0 N.D.
(#) = qualifier out of range (m) = manual integration
30695.D GCMS1126.M Fri Jan 18 11:06:43 2002 Page 1
NYC-WTC_000018109
OCR can misread numbers and units. Confirm readings against the page image before using them.