GCMS calibration table data, sample AE09677, May 2002

Machine-extracted title · confidence 90%

Calibration table listing response factors for deuterated standards and target compounds used in gas chromatography-mass spectrometry analysis.

NYC-WTC_000013184–000013190

Folder label: “GCMS X 5/21/02 A 5/21/02

Page image
Scanned page image, NYC-WTC_000013187
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

LSC Area Percent Report

pata File C:\HPCHEM\1\DATA\MAY0 602\9677.D Vial: 20 Acq On 7 May 2002 10:54 am Operator: Sample GC/MS SCAN 4/25 Inst : 209 Mise Multiplr: 1.00 MS Integration Params: LSCINT.P

Method : C:\HPCHEM\1\METHODS\GCMS0501.M (RTE Integrator) Title : 209 625/TCLP calibration table Smoothing : OFF Filtering: 5 Sampling : 1 Min Area: 1 % of largest Peak Start Thrs: 0.2 Max Peaks: 100 Stop Thrs : 0 Peak Location: TOP If leading or trailing edge < 100 prefer < Baseline drop else tangent > Peak separation: 5 Signal : TIC peak R.T. first max last PK peak peak peak % of # min scan scan scan TY height area % max. total 1 8.159 336 340 371 rVB 457770 1004028 18.97% 3.991% 2 12.191 775 780 797 rBV 1688038 3718093 70.23% 14.780% 3 15.829 1170 1177 1193 rBV 2336611 4755336 89.82% 18.903% 4 21.135 1749 1756 1775 rBV 2516631 5294038 100.00% 21.045% 5 23.270 1982 1989 1996 rBV 189574 372570 7.04% 1.481% 6 25.579 2233 2241 2250 rBV2 2232386 4873158 92.05% 19.372% 7 33.634 3113 3120 3136 rBV2 1291085 3015754 56.97% 11.988% 8 37.868 3573 3582 3600 rBV2 703996 2122883 40.10% 8.439%

Sum of corrected areas: 25155860 9677.D GCMS0501.M Thu May 09 11:25:17 2002

NYC-WTC_000013187

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000013187Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →