NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.7
Case folder · no pages saved yetReview case folder →
A question gets a cited answer. Keywords, addresses and Bates numbers go straight to the records.

Email alerts are not offered yet — copy this link to check back after a new release.

Searching the mirrored records for “asbestos”.

Ask this as a question →

7,936 document results

WTC Hotline call summary, May 8-9, 2002 — page 3

DEP Hard Copies (68 Boxes) / DEP Box 43 / E-mails 2002 M. Gilsenan
NYC-WTC_000162141Machine-extracted title
Memo or letter

Summary Daily summary of calls received by the WTC hotline regarding cleaning, health questions, and indoor air testing requests.

NYC 9/11 Public Portal Document Your apartment tested for asbestos in air (without cleaning): (If - and only if - asbestos is found during testing, you may

Volume NYC-WTC0006Agency: Environmental Protection, Dept. ofContaminants: asbestos

NYC-WTC_000153058 — page 7

DEP Hard Copies (68 Boxes) / DEP Box 26
NYC-WTC_000153064
Lab report

Asbestos medical experts we consulted agreed that professional cleaning was preferred for the asbestos contamination levels found, but at a minimum if the public was to clean

Volume NYC-WTC0006Agency: Environmental Protection, Dept. ofContaminants: asbestos, dust, lead

Law Department notice on WTC document preservation, Oct 2001 — page 182

DEP Hard Copies (68 Boxes) / DEP Box 08 / NO INFO
NYC-WTC_000145208Machine-extracted title
Lab report

Summary Notice from NYC Law Department instructing staff to preserve World Trade Center documents for potential legal actions.

Asbestos-containing materials on ventilation system components to be cleaned or damaged asbestos-containing materials in the vicinity of the ventilation system components to be cleaned. 4.

Volume NYC-WTC0006Agency: Environmental Protection, Dept. ofContaminants: asbestos, dust, lead, mold, silica

E-Mails Hotline M. Gilsenan — page 2

DEP Hard Copies (68 Boxes) / DEP Box 03 / E-Mails Hotline M. Gilsenan
NYC-WTC_000138384
Lab report

Building owners were also requested to have debris assessed for the presence of asbestos by a certified asbestos investigator.

Volume NYC-WTC0006Agency: Environmental Protection, Dept. ofContaminants: asbestos, debris

HVAC cleanup proposal for residential units, Feb 2003 — page 52

DEP Hard Copies (68 Boxes) / DEP Box 10 / EPA Indoor Air Cleanup
NYC-WTC_000148033Machine-extracted title
Chain of custody

Summary A project proposal outlining the timeline, methods, and justification for cleaning HVAC systems in residential units affected by World Trade Center dust.

o Asbestos Air Samples: 202 TEM samples were > 70 s/mm^ o Where asbestos abatement was performed and notifications of abatement were received, air sampling by a licensed air-monitoring

Volume NYC-WTC0006Agency: Environmental Protection, Dept. ofContaminants: asbestos, debris

Chain of Custody Form Instructions for WTC Building Sampling — page 69

DEP Hard Copies (68 Boxes) / DEP Box 10 / ATSDR/DHAC_ASTM
NYC-WTC_000149605Machine-extracted title
Chain of custody

Summary Instructions and sections for collecting sample location data from a specific building interior.

PLM testing did not detect levels of asbestos.

Volume NYC-WTC0006Agency: Environmental Protection, Dept. ofContaminants: asbestos, dust, gypsum, silica

Draft EPA OIG report excerpts on WTC indoor response, Oct — page 7

DEP Hard Copies (68 Boxes) / DEP Box 26 / WORLD TRADE CENTER EPA INSPECTOR GENERAL
NYC-WTC_000153503Machine-extracted title
Lab report

Summary Draft excerpts from an EPA Office of Inspector General report reviewing the World Trade Center indoor environmental response.

Asbestos medical experts we consulted agreed that professional cleaning was preferred for the asbestos contamination levels found, but at a minimum if the public was to clean

Volume NYC-WTC0006Agency: Environmental Protection, Dept. ofContaminants: asbestos, dust, lead

Draft document with asbestos data tables, DEP Box 09 — page 14

DEP Hard Copies (68 Boxes) / DEP Box 09
NYC-WTC_000147576Machine-extracted title
Lab report

Summary Draft record containing tabulated data regarding asbestos sampling or analysis at the World Trade Center recovery site.

The average detected asbestos concentration was 0.048 fibers/mL (note: fibers/mL and fibers/cc are interchangeable).

Volume NYC-WTC0006Agency: Environmental Protection, Dept. ofContaminants: asbestos, debris, dust, fiberglass, gypsum, silica

Memo on non-friable asbestos abatement policy, Feb 1999 — page 1

DEP Hard Copies (68 Boxes) / DEP Box 26
NYC-WTC_000153177Machine-extracted title
Permit application

Summary Memo clarifying enforcement policy for abating normally non-friable asbestos in single and two-family homes.

Portions of the regulated community (majority are public facilities) are filing ACP7, “Asbestos Project” notification for these materials.

Volume NYC-WTC0006Agency: Environmental Protection, Dept. ofContaminants: asbestos, lead

News article on asbestos-tainted WTC vehicles, August 2002 — page 1

DEP Hard Copies (68 Boxes) / DEP Box 08 / SCHOOLS
NYC-WTC_000144595Machine-extracted title
Lab report

Summary Newspaper report detailing city health department guidance for owners of vehicles contaminated with asbestos dust from the World Trade Center site.

10015 EMSL Project ID; Analysis Date 4/18/02 Asbestos

Volume NYC-WTC0006Agency: Environmental Protection, Dept. ofContaminants: anthophyllite, asbestos, chrysotile, debris

E-mails 2002 M. Gilsenan — page 2

DEP Hard Copies (68 Boxes) / DEP Box 43 / E-mails 2002 M. Gilsenan
NYC-WTC_000164188
Lab report

Building owners were also requested to have debris assessed for the presence of asbestos by a certified asbestos investigator.

Volume NYC-WTC0006Agency: Environmental Protection, Dept. ofContaminants: asbestos, debris

NYCDOH/ATSDR residential asbestos sampling results, April 2002 — page 8

DEP Hard Copies (68 Boxes) / DEP Box 44
NYC-WTC_000164967Machine-extracted title
Chain of custody

Summary Draft compilation of asbestos air samples collected from residential areas November-December 2001 by NYC DOH and ATSDR.

Asbestos and fibrous glass will be analyzed using New York State Method 198.1 (polarized light microscopy [PLM]); if <1% asbestos is found.

Volume NYC-WTC0006Agency: Environmental Protection, Dept. ofContaminants: asbestos, dust, gypsum, silica

Legal hold notice for WTC documents, undated — page 386

DEP Hard Copies (68 Boxes) / DEP Box 10 / AIR ASBESTOS MONITORING REPORTS
NYC-WTC_000148577Machine-extracted title
Lab report

Summary Notice instructing staff to preserve original World Trade Center documents for potential legal actions against the City.

Fresh Kills (Oct 12, 0600 - 1900 hrs) - Asbestos O All 17 samples were below the TEM AHERA standard.

Volume NYC-WTC0006Agency: Environmental Protection, Dept. ofContaminants: asbestos, dioxin

NYC DOH hotline Q&A on HVAC cleaning protocols and asbestos, — page 1

DEP Hard Copies (68 Boxes) / DEP Box 06 / DEP 59.17 Junction Blvd, 11th FL
NYC-WTC_000142730Machine-extracted title
Lab report

Summary Guidance document explaining requirements for HVAC cleaning and asbestos abatement regulations for building owners.

^ ■"greater than 1% asbestos requires that an asbestos abatement be performed in accordance with state and local (DEP) regulations.

Volume NYC-WTC0006Agency: Environmental Protection, Dept. ofContaminants: asbestos, debris

NYC DOH hotline Q&A on HVAC cleaning protocols and asbestos, — page 7

DEP Hard Copies (68 Boxes) / DEP Box 06 / DEP 59.17 Junction Blvd, 11th FL
NYC-WTC_000142747Machine-extracted title
Lab report

Summary Guidance document explaining requirements for HVAC cleaning and asbestos abatement regulations for building owners.

Studies of lung diseases caused by asbestos indicate that affected populations were exposed to large amounts of asbestos for long periods of time.

Volume NYC-WTC0006Agency: Environmental Protection, Dept. ofContaminants: asbestos, dust

NYCDOH/ATSDR asbestos residential sampling results, Apr 2002 — page 8

DEP Hard Copies (68 Boxes) / DEP Box 44
NYC-WTC_000164739Machine-extracted title
Chain of custody

Summary Draft spreadsheet of asbestos sampling results from residential locations collected November-December 2001, circulated for review.

Asbestos and fibrous glass will be analyzed using New York State Method 198.1 (polarized light microscopy [PLM]); if <1% asbestos is found.

Volume NYC-WTC0006Agency: Environmental Protection, Dept. ofContaminants: asbestos, dust, gypsum, silica

EPA OIG draft excerpt on WTC residential cleaning program, June — page 6

DEP Hard Copies (68 Boxes) / DEP Box 08 / EPA OIG LAW
NYC-WTC_000146127Machine-extracted title
Unclassified

Summary Draft excerpt describing the FEMA-funded residential testing and cleaning program administered by EPA and New York City following the attacks.

Under these circumstances, they should hire a certified asbestos cleanup contractor... " Asbestos medical experts

Volume NYC-WTC0006Agency: Environmental Protection, Dept. ofContaminants: asbestos, dust, lead

News article on community park spring cleaning event, 2001 — page 4

DEP Hard Copies (68 Boxes) / DEP Box 06 / DEP 59.17 Junction Blvd, 11th FL
NYC-WTC_000143028Machine-extracted title
Invoice

Summary Article describing a local community event where residents organized a spring cleaning of parks in Lower Manhattan.

who represents such asbestos victims, to asbestos suits.

Volume NYC-WTC0006Agency: Environmental Protection, Dept. ofContaminants: asbestos

EPA/NYC indoor air matrix, June 2002 — page 8

DEP Hard Copies (68 Boxes) / DEP Box 42 / E-mails R. Avaltroni 2002
NYC-WTC_000161188Machine-extracted title
Memo or letter

Summary Matrix of EPA and NYC indoor air quality activities for WTC response with cost estimates sent to FEMA coordinators.

(Scope 500 units to be (Asbestos B) cleaned.

Volume NYC-WTC0006Agency: Environmental Protection, Dept. ofContaminants: asbestos, dust

DEP advisory to residents regarding WTC dust, Oct 2001 — page 138

DEP Hard Copies (68 Boxes) / DEP Box 10 / ADVISORIES/FACT SHEETS
NYC-WTC_000149336Machine-extracted title
Lab report

Summary Department of Environmental Protection advisory letter dated October 25, 2001, addressed to residents of Lower Manhattan.

If TEM analysis shows asbestos fiber levels greater than 70structures/sq.mi 11 emeter it becomes an asbestos abatement project.

Volume NYC-WTC0006Agency: Environmental Protection, Dept. ofContaminants: asbestos