DEP Hard Copies (68 Boxes) / DEP Box 42 / WTC- Air Data
NYC-WTC_000161658Machine-extracted title FormSummary Agenda listing panelists from federal agencies, unions, and city departments for a March 2004 conference on post-9/11 air quality.
The quantitative wipe method for asbestos is ASTM
Method 6480, and was the method used by EPA in its 110 Liberty St.
cleaning study.
DEP Hard Copies (68 Boxes) / DEP Box 31 / 114 LIBERTY 1 OF 2
NYC-WTC_000154950Machine-extracted title Lab reportSummary Federal agencies respond to resident concerns regarding the validity of environmental clearance data for 114 Liberty Street.
Available at www.tera.org.) recently evaluated the technical soundness of
estimating airborne asbestos concentration as a function of asbestos
concentration in settled
DEP Hard Copies (68 Boxes) / DEP Box 31 / 114 LIBERTY 1 OF 2
NYC-WTC_000155004Machine-extracted title Lab reportSummary Federal agencies respond to resident concerns regarding the validity of environmental clearance data for 114 Liberty Street.
Available at www.tera.org.) recently evaluated the technical soundness of
estimating airborne asbestos concentration as a function of asbestos
concentration in settled
DEP Hard Copies (68 Boxes) / DEP Box 10 / OSHA_COSH
NYC-WTC_000149938Machine-extracted title Lab reportSummary Joint OSHA and Bechtel crane inspection report analyzing safety conditions at the World Trade Center site.
Reply: Bn. that the materials coirtaining asbestos were used in the constnxction of the ‘
Twin Towers, the settled dust from their collapse must be presumed to contain asbestos.
DEP Hard Copies (68 Boxes) / DEP Box 05 / EPA Cate Jenkins
NYC-WTC_000140054Machine-extracted title Chain of custodySummary Technical memorandum from EPA discussing ultrasonication testing for asbestos in carpets and HEPA vacuuming effectiveness.
See Table 2 for typical dust levels for buildings with or
without asbestos contamination problems.
DEP Hard Copies (68 Boxes) / DEP Box 05 / EPA Cate Jenkins
NYC-WTC_000140072Machine-extracted title Chain of custodySummary Technical memorandum from EPA discussing ultrasonication testing for asbestos in carpets and HEPA vacuuming effectiveness.
(March 11,2002) Status of air and dust asbestos testing after WTC collapse: 1.
Misrepresented “safe levels" and standards for asbestos; 2.
DEP Hard Copies (68 Boxes) / DEP Box 05 / EPA Cate Jenkins
NYC-WTC_000140099Machine-extracted title Chain of custodySummary Forwarded EPA memorandum dated June 9, 2002, concerning the Asbestos Reservoir and carpet testing methods.
See Table 2 for typical dust levels for buildings with or
without asbestos contamination problems.
DEP Hard Copies (68 Boxes) / DEP Box 08 / EPA OIG LAW
NYC-WTC_000146258Machine-extracted title Chain of custodySummary Correspondence from NYC Corporation Counsel providing comments on excerpts of a draft EPA evaluation report regarding the WTC response.
I understand that as the owner of a building where asbestos abatement activity occurs, I am responsible for the performance of
the asbestos abatement activities in accordance with the Asbestos Control Program Rules.
DEP Hard Copies (68 Boxes) / DEP Box 05 / EPA Cate Jenkins
NYC-WTC_000140117Machine-extracted title Chain of custodySummary Forwarded EPA memorandum dated June 9, 2002, concerning the Asbestos Reservoir and carpet testing methods.
(March 11.2002) Status of air and dust asbestos testing after WTC collapse: 1.
Misrepresented “safe levels" and standards for asbestos; 2.
DEP Hard Copies (68 Boxes) / DEP Box 11 / FORM LETTERS
NYC-WTC_000150065Machine-extracted title Memo or letterSummary Guidance issued by DEP to building owners outlining procedures for cleaning dust and debris potentially containing asbestos.
ACM is any material containing more that one percent asbestos.
DEP Hard Copies (68 Boxes) / DEP Box 11 / FORM LETTERS
NYC-WTC_000150067Machine-extracted title Memo or letterSummary Instructions for building owners regarding the safe removal of debris inside structures following the World Trade Center attack.
Only individuals certified by the NYC-DEP as asbestos handlers can
handle dust and debris accumulations identified to be ACM or asbestos-
contaminated
DEP Hard Copies (68 Boxes) / DEP Box 11 / FORM LETTERS
NYC-WTC_000150081Machine-extracted title Memo or letterSummary Instructions for building owners regarding the safe removal of debris inside structures following the World Trade Center attack.
Only individuals certified by the NYC-DEP as asbestos handlers can
handle dust and debris accumulations identified to be ACM or asbestos-
contaminated
DEP Hard Copies (68 Boxes) / DEP Box 11 / FORM LETTERS
NYC-WTC_000150083Machine-extracted title Memo or letterSummary Instructions for building owners regarding the safe removal of debris inside structures following the World Trade Center attack.
ACM is any material containing more that one
percent asbestos.
DEP Hard Copies (68 Boxes) / DEP Box 05 / EPA Cate Jenkins
NYC-WTC_000140151Machine-extracted title Lab reportSummary EPA memorandum addressing World Trade Center asbestos contamination status and agency efforts to provide information on the situation.
See Table 2 for typical dust levels for buildings with or
without asbestos contamination problems.
DEP Hard Copies (68 Boxes) / DEP Box 26
NYC-WTC_000152505Machine-extracted title InvoiceSummary An official press advisory announcing the cancellation of the 2001 deer hunting season and suspension of public access.
Cleveland’s Cuyahoga River, once Asbestos — the invisible, deadly
so polluted it caught fire.
DEP Hard Copies (68 Boxes) / DEP Box 08 / EPA OIG LAW
NYC-WTC_000146410Machine-extracted title Chain of custodySummary Correspondence from NYC Corporation Counsel providing comments on excerpts of a draft EPA evaluation report regarding the WTC response.
NYC 9/11 Public Portal Document
ad
’ ASBESTOS INSPECTION REPORT (continued) a, 2
26. Asbestos Hauler Jimmy Byme - JBT / IES!
DEP Hard Copies (68 Boxes) / DEP Box 05 / EPA Cate Jenkins
NYC-WTC_000140164Machine-extracted title Lab reportSummary EPA memorandum addressing World Trade Center asbestos contamination status and agency efforts to provide information on the situation.
(March 11,2002) Status of air and dust asbestos testing after WTC collapse: 1.
Misrepresented “safe levels" and standards for asbestos; 2.
DEP Hard Copies (68 Boxes) / DEP Box 11 / FORM LETTERS
NYC-WTC_000150120Machine-extracted title Memo or letterSummary Department of Environmental Protection memo instructing building owners on debris clean-up procedures.
Only individuals certified by the NYC-DEP as asbestos handlers can
handle dust and debris accumulations identified to be ACM or asbestos-
DEP Hard Copies (68 Boxes) / DEP Box 11 / FORM LETTERS
NYC-WTC_000150129Machine-extracted title Memo or letterSummary Cover sheet for a fax transmission from the Mayor's Office of Environmental Coordination dated September 26, 2001.
Only individuals certified by the NYC-DEP as asbestos handlers can
handle dust and debris accumulations identified to be ACM or asbestos-
contaminated
DEP Hard Copies (68 Boxes) / DEP Box 11 / FORM LETTERS
NYC-WTC_000150133Machine-extracted title Memo or letterSummary Department of Environmental Protection memo outlining procedures for cleaning asbestos-containing material.
ACM is any material containing more that one percent asbestos.