NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 05/EPA Cate Jenkins
Document / 42 pages

EPA memorandum regarding asbestos reservoir, June 2002

Machine-extracted title · confidence 50%

Forwarded EPA memorandum dated June 9, 2002, concerning the Asbestos Reservoir and carpet testing methods.

NYC-WTC_000140083–000140124

Folder label: “EPA Cate Jenkins

Page image
Scanned page image, NYC-WTC_000140099
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Table 3. ATSDR AIR LEVEL FINDINGS COMPARED TO LEVEL CHOSEN BY REGION 1

Background ambient air levels are from studies determined to be the most credible by the ATSDR®*

Concentration in TEM Equivalent concentration in structures per milliliter PCM fibers per milliliter (s/mL). This includes all (PCM f/mL). PCM fibers asbestos fibers and are only those single fibers bundles of fibers, and so which are longer than 5 is higher than “PCM” micrometers with a certain fibers. aspect ratio.

expressed as expressed as exponential exponential

ATSDR finding: outside air, rural, no 0.00001 (1 X 10’®) 0.0000002 (2x 10-’) known source of asbestos contamination nearby

ATSDR finding: outside air, urban, no 0.0001 (1 X 10^) 0.000002 (2x 10-®) know source of asbestos contamination nearby

ATSDR finding: 1988 EPA survey of 94 0.006 (6x 10-®) 0.0001 (1 X 10"*) public buildings containing asbestos materials, mean concentration

ATSDR finding: 1988 EPA survey of 41 0.03 (3x 10'2) 0.005 (5x 10-*) schools containing asbestos materials, mean concentration

AHERA TEM clearance test level, the “70 0.02 (2x 10^) 0.01 (1 X 10®) structures per square centimeter” level, approximately converted to s/mL and PCM equivalent f/mL. This is an unsafe level for long term exposures.’®

Region 1 level for background outside air, 0.045 (4.5 X 10’2) unknown used for risk assessment

Region 1 failed to use real-world background dust levels

There was no reason for Region 1 to have gone through any calculation process to project background dust levels from air levels. Typical background dust levels are well established, just like typical air levels.

Region 1 chose to ignore the fact that the same reference’® they used for K-factors also contained real world data for typical dust levels, which are widely recognized by industrial hygienists and other asbestos abatement specialists. See Table 2 for typical dust levels for buildings with or without asbestos contamination problems. Compare 200 s/cm^, a real world background level for buildings that do not contain asbestos materials, with Region I's calculated level of45,000 s/cm^.

-15-

NYC-WTC_000140099

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000140099Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →