Final Report Volume 1, WTC Unoccupied Building Monitoring, 125 Cedar — page 8
Summary Volume 1 of the final documentation report for the WTC unoccupied building monitoring program at 125 Cedar Street.
This allows for precise asbestos quantification.
Email alerts are not offered yet — copy this link to check back after a new release.
Searching the mirrored records for “asbestos”.
Summary Volume 1 of the final documentation report for the WTC unoccupied building monitoring program at 125 Cedar Street.
This allows for precise asbestos quantification.
Summary Instructions and sections for collecting sample location data from a specific building interior.
Asbestos and fibrous glass will be analyzed using New York State Method 198.1 (polarized light microscopy [PLM]); if <1% asbestos is found.
Summary Table listing volatile organic compound (VOC) sampling sites and dates outside of Ground Zero from September 2001 to January 2002.
samples daily Contract vocation V Pier 6, Bus Sign Asbestos 2-12 hour samples daily Contract vocation W Wash Tent, West Street Asbestos
Summary Forwarded spreadsheet compiling residential asbestos sampling results collected in November-December 2001, including Building 11 reoccupancy assessment.
Asbestos and fibrous glass will be analyzed using New York State Method 198.1 (polarized light microscopy [PLM]); if <1% asbestos is found, New York State Method 198.4 (transmission electron microscopy
Summary Series of emails forwarding a draft memo between DEP staff members for review and finalization.
Asbestos and fibrous glass will be analyzed using New York State Method 198.1 (polarized light microscopy [PLM]); if <1% asbestos is found.
Summary Transmission of revised asbestos sampling results for residential samples collected November-December 2001.
Asbestos and fibrous glass will be analyzed using New York State Method 198.1 (polarized light microscopy [PLM]); if <1% asbestos is found.
Summary US EPA Region 2 letter dated November 15, 2005, confirming completion of environmental review for abatement plans at 133-135 Greenwich Street.
Asbestos: Asbestos sample collection will be performed in accordance with NIOSH 7402, "Asbestos by TEM".
Summary A chain of custody cover sheet for air monitoring samples sent to the EPA Region 1 laboratory in January 2003.
NIOSH 7400 PCM > 5 um Mico vacuuin-ASTM D 24 hours 5755-95, wipc-ATSMD PCMc by TEM asbestos
Summary A chain of custody cover sheet for air monitoring samples sent to the EPA Region 1 laboratory in January 2003.
Wipc-ATSMD PCMc by TEM asbestos only > 5 um 6480-99, air-NIOSH 7400, Standard (3 days) and bulk
Summary EPA Region 2 letter regarding revised environmental work plan submission for two buildings including asbestos, health, and safety assessment components.
Asbestos: Asbestos sample collection will be performed in accordance with NIOSH 7402, "Asbestos by TEM".
Summary Part II of a permit application dated January 10, 2006 for air monitoring during remediation at 30 West Street.
Notes on Community Air Monitoring Table: Asbestos: Asbestos sample collection will be performed in accordance with NIOSH 7402, "Asbestos by TEM".
Summary Part III of an air monitoring plan for remediation and deconstruction at 30 Warren Street in January 2006.
Notes on Community Air Monitoring Table: Asbestos: Asbestos sample collection will be performed in accordance with NIOSH 7402, "Asbestos by TEM".
Summary Technical attachment specifying ASTM methods for collecting and analyzing asbestos and lead in settled dust from residential surfaces.
This was decided since pulverized silica would be particulate like and not fiber like as with asbestos and MMVF. NYC-WTC_000140461
Summary EPA correspondence transmitting draft letter to FEMA regarding 114 Liberty with attached documentation and data receipt timeline.
Included in the letter was reaffirmation of DEP’s Asbestos Control Program’s staff observations whereby pre-existing building materials were identified as having suspect asbestos-containing material
Summary OCR-distorted text listing media types and analytical parameters for World Trade Center environmental monitoring.
This was decided since pulverized silica would be particulate like and not fiber like as with asbestos and MMVF.
Summary A Department of Environmental Protection letter dated April 24, 2003, confirming the completion of clean-up activities and clearance levels at 114 Liberty Street.
a Asbestos — Eighty-eight air samples were collected before and/or during cleaning events.
Summary EPA letter confirming that primary and secondary clearance levels for asbestos and other contaminants were met at 114 Liberty Street.
Asbestos — Eighty-eight air samples were collected before and/or during cleaning events.
Summary Chain of custody document tracking the collection and transport of asbestos bulk samples for analysis.
a Asbestos — Eighty-eight air samples were collected before and/or during cleaning events.
Summary Laboratory analysis results for asbestos content in beige bulk samples collected from a pizzeria on one of the building floors.
a Asbestos — Eighty-eight air samples were collected before and/or during cleaning events.
Summary Laboratory analysis results for asbestos content in beige bulk samples collected from a pizzeria on one of the building floors.
a Asbestos — Eighty-eight air samples were collected before and/or during cleaning events.