Air sampling summary letter, 225 Rector Place, Jan 2002 — page 158
Summary Letter from environmental consultants summarizing ambient air sampling and cleanup activities at 225 Rector Place.
Asbestos .meIC tow e.ot Method: Q 0CP.
Email alerts are not offered yet — copy this link to check back after a new release.
Searching the mirrored records for “asbestos”.
Summary Letter from environmental consultants summarizing ambient air sampling and cleanup activities at 225 Rector Place.
Asbestos .meIC tow e.ot Method: Q 0CP.
Summary Form documenting the tracking and handling of environmental samples collected by the Department of Environmental Protection.
Specifically, the peer review panel (www.tcra.org) stated: "The panel did not endorse the asbestos settled dust benchmark because the only relevant exposure pathway for asbestos is inhalation
Summary Cover page for a survey report detailing asbestos and lead-based paint findings at 130 Cedar Street.
CAUTION: Other fibers with optical properties similar to asbestos may give positive interferences and will be considered asbestos under this methodology.
Summary Cover page for a survey report detailing asbestos and lead-based paint findings at 130 Cedar Street.
CAUTIjON: Other fibers with optical properties similar to asbestos may give positive interferences and will be considered asbestos under this methodology.
Summary Cover page for a survey report detailing asbestos and lead-based paint findings at 130 Cedar Street.
CAUTION: Other fibers with optical properties similar to asbestos may give positive interferences and will be considered asbestos under this methodology.
Summary DEP report detailing the methodology and standards for monitoring outdoor air quality for asbestos fibers in Lower Manhattan.
This measurement protocol is called transmission y^Asbestos electron microscopy (TEM) and counts the number of asbestos fibers in the sample.
Summary Fragmented record associated with the 80 West Street and Financial Center folder in DEP Box 53.
Air samples were taken to assess the airborne asbestos levels and dust/ debris samples were collected to ■ characterize the asbestos content of the debris within the building.
Summary Letter enclosing two reports summarizing asbestos testing data for 41 Park Row sent to the DEP.
West Tower Lobby / 01204-54 13:38— 16:10 No Asbestos Structures Detected North Lobby AC B- Level West Tower, Student Union / 01204-55 13:42 — 16:15 No Asbestos Structures
Summary NYC DEP Asbestos Project Notification form submitted for an inspection or abatement project at 250 South End Avenue.
NYC DEP ASBESTOS CONTROL PROGRAM EMERGENCY ASBESTOS PROJECI, NOTIFICAXo .5RCN Sects
Summary NYC DEP asbestos project notification form submitted for an inspection report at 15 Maiden Lane.
NYC 9/11 Public Portal Document NYC DSP ASBESTOS CONTROL PROGRAM • 5M5RQ5NCIC ASBESTOS PROJZCT (OTIF=CATION (15
Summary Cover page for an asbestos project notification form submitted to the New York City Department of Environmental Protection.
I understand that as the owner of a building where asbestos abatement activity occurs, I am responsible for the asbestos abatement activities in accordance with the
NYC 9/11 Public Portal Document ASBESTOS INSPECTION REPORT (continued) zu.
Summary Memo describing DEP's outdoor asbestos air monitoring network, testing methods (PCM/TEM), and lack of national outdoor standards.
The TEM test shows whether or not the fibers collected in the sample are actually asbestos fibers. There is no national standard for asbestos in OUTDOOR AIR.
Summary Log of calls received by the DEP regarding survivor needs for medical aid and resources at the site.
EPA can measure asbestos in several ways.
Summary A project proposal outlining the timeline, methods, and justification for cleaning HVAC systems in residential units affected by World Trade Center dust.
The TEM test shows whether or not the fibers collected in the sample are actually asbestos fibers. There is no national standard for asbestos in OUTDOOR AIR.
Summary Chain of custody documentation for bulk sampling and air monitoring at 365 South End Avenue Building 300.
-"Asbestos in Friable Sut7acinY Materials."
Summary Documentation tracking the chain of custody for environmental samples collected from Building #400 at 375 South End Avenue in October 2001.
The following personnel were used to perform asbestos air monitoring and/or asbestos inspections. Project Manager Inspector/Project Monitor: Americo Rodriguez Jr.
Summary Laboratory report on TEM analysis of carpet mastic glue samples from residential building common corridors confirming absence of asbestos.
ENTIRE HALLWAYS Analysis Date 11/27/02 Asbestos Analysis of Non -Friable Organically
Summary A document label identifying bulk and air sample locations at 170 Broadway with a tracking number.
1) For the areas where bulk sampling has indicated that asbestos is content) or are assumed to contain asbestos materials, a New York State Licensed Asbestos
Summary A cover letter accompanying chain-of-custody forms for asbestos air and dust samples collected at 176 Broadway in September 2001.
PCM laboratory analysis method does not distinguish between asbestos fibers and non-asbestos fibers.