Comments recommending removal of respirator sections from EPA report — page 11
Summary Document arguing that respirator safety issues fall under OSHA jurisdiction and should be removed from the EPA review.
with asbestos abatement procedures.” 16.
Email alerts are not offered yet — copy this link to check back after a new release.
Searching the mirrored records for “asbestos”. Semantic ranking is unavailable (ollama http 502); showing keyword-only results.
Summary Document arguing that respirator safety issues fall under OSHA jurisdiction and should be removed from the EPA review.
with asbestos abatement procedures.” 16.
Summary Internal memo forwarding a revised document to the Law Department for review.
accordance with asbestos abatement procedures.” 16.
Summary City law department correspondence coordinating response to EPA with proposed changes to respirator requirements and related policies.
in accordance with asbestos abatement procedures.” 16.
Summary EPA news summary dated October 14, 2001, regarding environmental monitoring data collected from the World Trade Center site.
One sample (bulk steel) contained 2.68% asbestos (chrysotile).
Summary Air monitoring report for 345 South End Avenue buildings conducted in January 2002 showing TEM results.
The number of structures - material that has asbestos fibers on or in it - is then counted.
Summary Letter from Enviroscience Consultants providing air sampling results for the SIAC at 86 Trinity Place.
Structures are fibers, clusters, bundles, and matrixes that contain asbestos fibers greater than 0.5 micrometers in length.
Summary Memo reporting air sampling results conducted December 2-3, 2001, at the SIAC and Exchange locations.
The filter concentration is multiplied by the filter area produce the asbestos air concentration.
Summary Memo reporting air sampling results for December 2-3, 2001 at the SIAC Exchange building.
Structures are fibers, clusters, bundles, and matrixes that contain asbestos fibers greater than 0.5 micrometers in length.
and mercury in following procedures established in the WTC Indoor Air Pre-Cleanup Pilot Study. 2) Air samples should be collected for asbestos, fibrous glass and silica.
Summary Forwarding EPA sampling recommendations for incorporation into scope of work for 125 Cedar and 114 Liberty buildings.
silica) and mercury in following procedures established in the WTC Indoor Air Pre-Cleanup Pilot Study. 2) Air samples should be collected for asbestos, fibrous glass and silica.
and mercury in following procedures established in the WTC Indoor Air Pre-Cleanup Pilot Study. 2) Air samples should be collected for asbestos, fibrous glass and silica.
Summary EPA technical recommendations and protocol for environmental sampling activities at 125 Cedar.
) and mercury in following procedures established in the WTC Indoor Air Pre-Cleanup Pilot Study. 2) Air samples should be collected for asbestos, fibrous glass and silica.
Summary Form documenting the tracking and handling of environmental samples collected by the Department of Environmental Protection.
Comparison of asbestos air samples that were collected using modified-aggressive and aggressive air disturbance.
Summary Form authorizing the City of New York to proceed with obligations related to FEMA emergency management programs for WTC cleanup.
Monitors must have served as a third party project monitor on at least 20 asbestos abatement projects.
Summary Correspondence from NYC Corporation Counsel providing comments on excerpts of a draft EPA evaluation report regarding the WTC response.
Residential Environmental Sampling-Lower Manhattan, Asbestos In Dust (PLM), November 4-December 11, 2001 Figure 9.
Summary Table listing volatile organic compound (VOC) sampling sites and dates outside of Ground Zero from September 2001 to January 2002.
includes all asbestos fibers greater than 5 microns in length. 4.
Summary EPA sends sampling recommendations and attached documents for 125 Cedar Street.
and mercury in following procedures established in the WTC Indoor Air Pre-Cleanup Pilot Study. 2) Air samples should be collected for asbestos, fibrous glass and silica.
Summary A twelve-page document excerpt defining terms related to public sewer use and industrial waste discharge under NYC DEP regulations.
Asbestos Dissemination Prevention Methods (ate Section F.
Summary Legal firm transmits confidential information regarding environmental work to EPA Region 2 via fax.
Mike Gilsenan advised that when Deutsche Bank was built, asbestos was no longer used in construction.
sent to an accredited Iaboratory, asbestos and found not to be asbestos containing.