NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 15 pages

Site sampling general procedures, field investigation

Machine-extracted title · confidence 44%

Overview of standard operating procedures for collecting soil, water, sediment samples at various locations.

NYC-WTC_000455821–000455835
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

b. Instead of using a personal sampling pump, attach the silicon tubing to the probe and a PID or FID. Once a steady reading is obtained, the system is considered to be in equilibrium. (Not recommended if low levels of volatile organic vapors are present [i.e., <1 ppm]).

6.4 Soil (Surface)

1. Be certain that the sample location is noted on Location Sketch (see Section 8.1).

2. If a dedicated sampling device is not used, be certain that the sampling equipment has been decontaminated utilizing the procedures outlined in Section 6.0.

3. Remove laboratory precleaned sample container from sample cooler, label container with an indelible marker, fill out Sample Information Record and Chain of Custody Form (see Section 8.0).

4. At the sample location, clear surface debris (e.g., vegetation, rocks, twigs, etc.). Collect an adequate amount of soil from a depth of 0 to 3 inches using a decontaminated or disposable scoop and/or sterile wooden tongue depressor. Transfer the sample directly into the sample container.

5. Return the sample container to the cooler.

6. If reusable, decontaminate the sampling equipment according to the procedures described in Section 6.0.

7. Place all disposable personal protective equipment and disposable sampling equipment into a 55-gallon drum and store in a secure area (fenced, if possible).

6.5 Sediment (Dry Wells, Catch Basins, Wastewater Disposal/Sanitary Systems, Storm Drains)

1. Be certain that the nondisposable sampling equipment (e.g., long handle polyethylene scoop) has been decontaminated utilizing the procedures outlined in Section 6.0.

2. Remove laboratory precleaned sample containers from sample cooler, label container with an indelible marker, fill out Sample Information Record and Chain of Custody Form.

3. Insert scoop slowly at 0-6 inches into the sediment and remove sample. Sample sediment only after surface water samples have been taken to avoid introduction of sediment into the water.

4. If depth to sediment is greater than the reach of a long handled scoop, the sample may

eD1519\A0930701.doc 6-8

CITY_21MC100_0 09947933

NYC-WTC_000455828

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000455828Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →