arrival at the laboratory.

All necessary documentation required to accompany the sample during shipment will be placed in a sealed plastic bag and taped to the underside of the cooler lid. The cooler will then be sealed with fiber (duct) or clear packing tape, and custody seals will be placed in such a manner that any opening of the cooler prior to arrival at the laboratory can be detected.

All samples will be shipped to ensure laboratory receipt within 48 hours of sample collection in accordance with NYSDEC and USEPA requirements. The laboratory will be notified prior to the shipment of the samples.

6.3 Soil Vapor

1. Be certain that the sample location is noted on Location Sketch (see Section 8.1).

2. Drive the decontaminated stainless steel probe with removable inner rod into the ground to the desired depth.

3. Remove inner rod and immediately replace with a stainless steel cap equipped with a sampling port.

4. Connect new silicon tubing to the probe and the personal sampling pump. Turn on pump. Allow the pump to run until the soil vapor within the probe has reached equilibrium.*

5. Collect a 100 to 500 Lil vapor sample using a gas tight syringe and inserting it into the silicon tubing. Transport sample to the portable gas chromatograph (GC) analyst.

6. Shut off pump and disconnect tubing.

7. Extract probe from the ground and decontaminate according to the procedures in Section 6.0.

*In order to establish how long it takes for the soil vapor to reach equilibrium in the probe, two approaches can be utilized:

a. Once the pump is turned on, collect a sample every one to two minutes and analyze on the portable GC. Continue to collect samples until two consecutive samples yield comparable results. Do this at two or three locations in order to establish a pumping time.

eD1519\A0930701.doc 6-7

CITY_21MC100_0 09947932

NYC-WTC_000455827

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000455827Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →