Table 6-1 (continued)

SUMMARY OF SAMPLING PROGRAM

Environmental Media Sample Location Sample Point Sample Depth Equipment Rationale Sample Analysis

Subsurface Soil On-site Monitoring well Dependent on Auger, decontaminated To determine TCL -1-30 and TAL borehole/soil visual charac­ split spoon and sterile subsurface soil parameters boring teristics and wooden tongue contamination 1995 NYSDECASP total organic depressor vapor field screening

Subsurface Soil On-site Probe location Dependent on Decontaminated probe To determine TCL +30 and TAL visual charac­ and polyethylene subsurface soil parameters teristics and tube liner contamination 1995 NYSDECASP total organic vapor field screening

Groundwater On-site Probe location At surface of Disposable polyetlrylene To determine TCL -1-30 and TAL water in probe tubing with bottom check groundwater parameters valve contamination 1995 NYSDECASP

Groundwater On-site Hydropunch At surface of Disposable polyethylene - To determine TCL -1-30 and TAL location water in screen small diameter bailer groundwater parameters contamination 1995 NYSDECASP

Groundwater On-site Monitoring well At surface of Disposable polyethylene To determine TCL -1-30 and TAL water in well bailer (after purge of groundwater parameters three well volumes) contamination 1995 NYSDECASP

Water Supply On-site Prior to treatment NA Sample container To determine TCL -1-30 and TAL system, if possible, directly after water supply parameters or from faucet running water contamination 1995 NYSDECASP for 5 minutes O

H Air On-site Ambient Air Breathing Zone Personal sampling To determine TCL VOC pump and dedicated air contamination EPA 600/4-89/017 sorbent tube and worker exposure s O O O I o o

aC1519\A0930701.doc sc to co 6-3

NYC-WTC_000455823

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000455823Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →