NYC-WTC_000361661
Final air monitoring and bulk sampling report for PS 89M area, Oct 2001.
6 shared non-person entities · similarity 0.931
machine-extracted · confidence unavailable · Check page ↗Final report for project N/A, prepared by Warren & Panzer Engineers; confidential info.
NYC-WTC_000247380–000247450OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Warren & Panzer Engineers, P.C. City of New York - Department of Design and Construction Peck Slip, Manhattan
c TAGM provides guidance for remedial actions at NYSDEC Inactive Hazardous Waste and Spill sites, based on health-related concerns and available clean-up technologies.
The NYSDEC Spill Technology and Remediation Series (STARS) Memo #1 provides TCLP Alternative Guidance Values.
The TCLP results have been compared with EPA regulatory levels for Characteristics of Hazardous Waste published in Resource Conservation and Recovery Act (RCRA) Title 40- Part 261 (40 CFR 261) revised as of July 1, 1999 and the NYC Department of Sanitation Criteria to Evaluate Soil as Cover Material for Use at the Fresh Kills Landfill.
The groundwater samples were analyzed for parameters put forth by the New York City Department of Environmental Protection (NYCDEP) Bureau of Wastewater Pollution Control Division of Pollution Prevention and Monitoring Industrial Pretreatment Program Inspection and Permit Section. This analysis includes Metals by EPA Method 200 series (Cr VI by SMI83500), c Oil and Grease by EPA Method 413.1, Total Suspended Solids by EPA Method 160.2, Flash Point by EPA Method 1010, pH by EPA Method 150.1, PCBs by EPA Method 608 (parts per trillion), and selected Volatile Organic Compounds by EPA Method 8260. The groundwater analytical results were compared to the NYCDEP Limitations for Effluent to Sanitary or Combined Sewers.
3.1.1. J Volatile Organic Compounds (VOCs) in Soil VOCs were detected in the samples collected from ENV-2 (south side of Front Street adjacent to 237 Front Street) and ENV-3 (northeast comer of Front Street and Beekman Street). VOCs were not detected at concentrations exceeding the NYSDEC TAGM 4046 RSCO and only one (1) VOC was detected above the STARS Memo #1 TCLP Alternative Guidance Values. The following is a description of the VOCs that were detected above laboratory detection limits: Benzene Benzene was detected in the soil sample collected from ENV-2 (0-5) at a concentration of 15 parts per billion (ppb). This exceeds the STARS Alternative
c Guidance Value of 14 ppb.
Warren & Panzer Project ID No. 1208.43.01 ., FINAL- September 30, 2004 DDC CAPIS ID No. HWMl 159/HWMWTCA7D Work Order Letter No. 1355-W&P2R-I455
CONFIDENTIAL INSURANCE INFORMATION, CITY_2IMCl00_008634568 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000247393
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000361661
Final air monitoring and bulk sampling report for PS 89M area, Oct 2001.
6 shared non-person entities · similarity 0.931
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000356874
Analytical results summary for soil and water samples; TAGM standards referenced.
6 shared non-person entities · 1 shared topics · similarity 0.931
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000150466
Fax cover sheet from the New York City Department of Health Lead Poisoning Prevention Program.
17 shared non-person entities · similarity 0.944
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000130926
Letter from a company to DEP confirming minimal dust and cleaning at 1 Battery Park Plaza following the September 11 attacks.
19 shared non-person entities · similarity 0.939
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000105236
Report presenting findings from bulk soil and surface wipe sampling at West Thames Park in Battery Park City.
16 shared non-person entities · 1 shared topics · similarity 0.937
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000132178
Cover letter transmitting lead in dust sampling results for the 12th floor of 114 Liberty Street.
5 shared non-person entities · 1 shared topics · similarity 0.934
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000337971
Laboratory report listing PAH compounds and concentrations from WTC site samples.
1 shared non-person entities · 1 shared topics · similarity 0.934
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000105336
Letter enclosing air sampling results and cleaning details for 70 Battery Place conducted in November 2001.
13 shared non-person entities · similarity 0.933
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000409569
TEM analysis of air samples from Building 200, Oct 2001.
2 shared non-person entities · similarity 0.932
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000331130
Analytical results and guidelines from STL Edison for WTC site samples.
9 shared non-person entities · 1 shared topics · similarity 0.932
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000302808
Results from sampling platform near World Trade Center; metals, PCBs, PAHs analyzed.
9 shared non-person entities · 1 shared topics · similarity 0.932
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000135145
EPA/DEP memo discussing initial findings from PCB analysis of caulking and dust samples, with risk-based screening criteria evaluation.
9 shared non-person entities · similarity 0.931
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000321344
Particulate results below OSHA TWA at L, N, R; detailed station readings included.
Similarity score 0.949 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000141585
Map showing the condition of buildings at the World Trade Center site as of September 21, 2001.
Similarity score 0.947 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000247094
Table of contents for a project report with sections on topography and geology.
Similarity score 0.945 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000454657
Protocol for soil and groundwater testing to support NYC infrastructure projects.
Similarity score 0.944 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000418708
Hazardous materials screening study for GEIS at World Trade Center site areas.
Similarity score 0.943 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000236859
Summary of environmental sampling results showing no detectable asbestos fibers at PS/IS 89 in January 2002.
Similarity score 0.943 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000150466
Fax cover sheet from the New York City Department of Health Lead Poisoning Prevention Program.
Similar indexed content
Letter from a company to DEP confirming minimal dust and cleaning at 1 Battery Park Plaza following the September 11 attacks.
Similar indexed content
NYC-WTC_000105236
Report presenting findings from bulk soil and surface wipe sampling at West Thames Park in Battery Park City.
Similar indexed content
NYC-WTC_000132178
Cover letter transmitting lead in dust sampling results for the 12th floor of 114 Liberty Street.
Similar indexed content
NYC-WTC_000337971
Laboratory report listing PAH compounds and concentrations from WTC site samples.
Similar indexed content