NYC-WTC_000454531
Sampling and analysis quality control requirements for CLP methods and duplicates.
2 shared non-person entities · similarity 0.931
machine-extracted · confidence unavailable · Check page ↗Overview of standard operating procedures for collecting soil, water, sediment samples at various locations.
NYC-WTC_000455821–000455835OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Table 6-1
SUMMARY OF SAMPLING PROGRAM
Environmental Media Sample Location Sample Point Sample Depth Equipment Rationale Sample Analysis
Soil Vapor On-site Soil vapor survey 3 feet below Decontaminated or To determine TCL volatile parameters point soil surface disposable soil vapor rods/ soil contamination EPA 600/4-89/017 or tubing, gas tight syringe select VOCs by Portable or sorbent tube and GC (EPA Method 601) personal sampling pump
Surface Soil On-site Throughont site- 0-3 inches Disposable polyethylene To determine TCL +30 and TAL below soil scoop and/or sterile wooden surface soil parameters surface tongue depressor contaniiiiatioii 1995 NYSDECASP
Subsurface Soil On-site Test pit Dependent on Decontaminated To determine TCL +30 and TAL visual charac backhoe bucket, disposable subsurface soil parameters teristics and polyethylene scoop and contamination 1995 NYSDEC ASP total organic sterile wooden tongue vapor field depressor screening
SedimentySludge On-site Dry well/catch 0-6 inches below Decontaminated To determine TCL +30 and TAL basin/wastewater/ sediment surface polyethylene scoop sediment parameters sanitary system/storm or split spoon sampler contamination 1995 NYSDECASP drain
Wastewater On-site Wastewater/ 6 inches below Decontaminated long To determine TCL +30 and T AL Sanitary System water surface handle polyethylene drainage wastewater parameters scoop or polyethylene contamination 1995 NYSDECASP bailer
Drainage/Storm Water On-site Dry well/catch basin/ 6 inches below Decontaminated long To determine TCL +30 and TAL storm drain water surface handle polyethylene storm water parameters scoop or polyethylene contamination 1995 NYSDECASP bailer
O
H
s O O O I o o
aC1519\A0930701.doc sc to 6-2
NYC-WTC_000455822
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000454531
Sampling and analysis quality control requirements for CLP methods and duplicates.
2 shared non-person entities · similarity 0.931
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000455639
Generic site investigation protocol for underground storage tank program; contractor roles and standards.
3 shared non-person entities · similarity 0.951
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000437748
EPA-compiled plan for Environmental Community Air Monitoring Program, 2005.
2 shared non-person entities · similarity 0.932
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000423012
EPA review/approval notes for WTC sampling document.
2 shared non-person entities · similarity 0.931
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000321809
Procedural table for collecting samples using Nilfisk equipment.
1 shared non-person entities · similarity 0.931
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000219925
Document excerpt of 40 CFR Part 763 Appendix A detailing mandatory and non-mandatory analytical methods for asbestos in schools as of January 2002.
1 shared non-person entities · similarity 0.918
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000164417
Chain of custody records and emails forwarding the ATSDR residential and commercial interior sampling program draft.
3 shared non-person entities · 1 shared topics · similarity 0.918
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000290274
EPA guidance on mandatory and nonmandatory TEM methods for asbestos analysis.
1 shared non-person entities · similarity 0.917
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000302886
Draft plan for environmental monitoring of exposure to fibers after WTC collapse.
2 shared non-person entities · 1 shared topics · similarity 0.916
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000389978
Policy language on clean areas, HEPA filtration, and sampling expectations for asbestos work.
1 shared non-person entities · similarity 0.916
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000250451
Final draft of ambient and indoor dust evaluation protocol for WTC area.
3 shared non-person entities · 1 shared topics · similarity 0.916
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000275357
Appendix description for TEM and related methods for asbestos analysis in air samples.
1 shared non-person entities · similarity 0.915
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000454531
Sampling and analysis quality control requirements for CLP methods and duplicates.
Similarity score 0.937 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000430553
EPA report index and references for NYC WTC samples; Region 1 coordination.
Similarity score 0.937 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000417776
Index page for US EPA Region 1 materials related to NYC WTC sampling, April 2003 edition.
Similarity score 0.937 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000454531
Sampling and analysis quality control requirements for CLP methods and duplicates.
Similarity score 0.937 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000247380
Final report for project N/A, prepared by Warren & Panzer Engineers; confidential info.
Similarity score 0.937 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000247380
Final report for project N/A, prepared by Warren & Panzer Engineers; confidential info.
Similarity score 0.936 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000455639
Generic site investigation protocol for underground storage tank program; contractor roles and standards.
Similar indexed content
NYC-WTC_000437748
EPA-compiled plan for Environmental Community Air Monitoring Program, 2005.
Similar indexed content
NYC-WTC_000423012
EPA review/approval notes for WTC sampling document.
Similar indexed content
NYC-WTC_000454531
Sampling and analysis quality control requirements for CLP methods and duplicates.
Similar indexed content
NYC-WTC_000321809
Procedural table for collecting samples using Nilfisk equipment.
Similar indexed content