Staten Island asbestos sampling, Nov 13 2001

Machine-extracted title · confidence 52%

Asbestos air sampling results for Staten Island with TEM/PCM analyses.

NYC-WTC_000455427
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

NYC Response Asbestos Air Sampling Results for Staten Island Landfill Sampling Date and Times: 11/13/01 1900 to 11/14/01 0750 Data Validation Date: 11/15/01

PCM by NIOSH 7400 TEM (AHERA) Sampling Sampling Sample Structures (#) Date Sample No. Location Volume* Matrix f/mm^ f/cc 0.5p - 5p 5p S/mm^ S~f/cc** 11/13/01 LF00629 P-1 681 Air <7.0 <0.004 0 0 <8.75 <0.0049 11/13/01 LF00630 P-2 708 Air <7.0 <0.004 0 0 <8.75 <0.0048 11/13/01 LF00631 P-3 707 Air <7.0 <0.004 0 0 <8.75 <0.0048 11/13/01 LF00632 P-4 708 Air <7.0 <0.004 2*.. 0 17.5 0.0095 11/13/01 LF00633 P-5 707 Air <7.0 <0.004 0 0 <8.75 <0.0048 11/13/01 LF00634 P-6 707 Air <7.0 <0.004 0 8.75 0.0048 11/13/01 LF00635 P-7 703 Air <7.0 <0.004 0 0 <8.75 <0.0048 11/13/01 LF00636 P-8 707 Air <7.0 <0.004 0 0 <8.75 <0.0048 11/13/01 LF00637 S-9A 720 Air <7.0 <0.004 0 0 <8.75 <0.0047 11/13/01 LF00638 S-9B 709 Air <7.0 <0.004 0 0 <8.75 <0.0048 11/13/01 LF00639 S-10A 707 Air <7.0 <0.004 0 0 <8.75 <0.0048 11/13/01 LF00640 S-10B 697 Air <7.0 <0.004 0 0 <8.75 <0.0048 11/13/01 LF00641 W-11 702 Air 16.56 0.009 0 8.75 0.0048 11/13/01 LF00642 W-12A 720 Air 42.04 0.022 0 17.5 0.0094 7777 11/13/01 LF00643 W-12B 720 Air <7.0 <0.004 0 8.75 0.0047 11/13/01 LF00644 B-13 706 Air <7.0 <0.004 0 0 <8.75 <0.0048 11/13/01 LF00645 B-14 706 Air <7.0 <0.004 0 0 <8.75 <0.0048 11/13/01 LF00646 T-15 720 Air 28.03 0.015 0 0 <8.75 <0.0047 11/13/01 LF00647 T-16 720 Air 17.20 0.009 0 0 <8.75 <0.0047 11/13/01 LF00648 Lot Blank 0 Air <7.0 n/a 0 0 <8.75 n/a 11/13/01 LF00649 Trip Blank 0 Air <7.0 n/a 0 0 <8.75 n/a

Key: * Sample volume (liters) is below recommended limit for the TEM method; volume is based on pump reading ** Structure (S) is roughly equivalent to fiber (f) *** Chrysotile n/a - Not applicable

NIOSH 7400: Fiber Analysis of Air samples via NIOSH 7400, Revision 3, Issue 2, 8/15/94 Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) EPA 40CFR Part 763 (AHERA) standard criteria: EPA 40CFR Part 763 (AHERA): 0.01 fiber/cc (PCM), 70 S mm\ volume 1200 L, tor 25 mm tiller (TEM) o H

S o O O Io o co cn co OEM000056851 cn co

NYC-WTC_000455427

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000455427Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →