NYC Response Asbestos Air Sampling Results for Staten Island Landfill Sampling Date and Times: 12/26/01 0753 to 2203 Data Validation Date: 12/30/2001

PCM by NIOSH 7400 TEM AHERA) Sampling Sampling Sample Structures (#) Date Sample No. Location Volume* Matrix f/mm^ f/cc 0.5p - 5p S/mm^ S~f/cc‘* 12/26/01 LF01793 P-1 720 Air <7.0 <0.004 0 0 <8.75 <0.0047 12/26/01 LF01794 P-2 578 Air 10.19 0.007 0 8.75 0.0058 12/26/01 LF01795 P-3 720 Air 7.64 0.004 - 0 0 <8.75 <0.0047 12/26/01 LF01796 P-4 720 Air <7.0 <0.004 0 0 <8.75 <0.0047 12/26/01 LF01797 P-5 720 Air 7.64 0.004 0 0 <8.75 <0.0047 w 12/26/01 LF01798 P-6 720 Air <7.0 <0.004 0 0 <8.75 <0.0047 G 12/26/01 LF01799 P-7 720 Air <7.0 <0.004 0 0 <8.75 <0.0047 K G 12/26/01 LF01800 P-8 720 Air <7.0 <0.004 0 0 <8.75 <0.0047 M W-11 720 Air 10.19 0.005 0 /J **** 8.75 0.0047 12/26/01 LF01801 O H 12/26/01 LF01802 W-12A 720 Air 20.38 0.011 0 0 <8.75 <0.0047 12/26/01 LF01803 W-12B 720 Air 9.55 0.005 0 0 <8.75 <0.0047 H 2*.. O 12/26/01 LF01804 B-13 720 Air 12.74 0.007 0 17.50 0.0094 LF018D5 B-14 NS Air NS NS NS NS NS NS 12/26/01 LF01806 T-15 720 Air 14.65 0.008 0 0 <8.75 <0.0047 o 12/26/01 LF01807 T-16 720 Air 14.01 0.0075 0 8.75 0.0047 H M 12/26/01 LF01808 0-17 720 Air <7.0 <0.004 0 0 <8.75 <0.0047 O o 12/26/01 LF01809 0-18 720 Air <7.0 <0.004 0 0 <8.75 <0.0047 H o s 12/26/01 LF01810 0-19 533 Air <7.0 <0.004 0 0 <8.75 <0.0063 < 12/26/01 LF01811 MPHS-20 707 Air 7.64 0.004 0 0 <8.75 <0.0048 M a 12/26/01 LF01812 Lot Blank 0 Air <7.0 n/a 0 0 NA® NA«> o M s 12/26/01 LF01813 Trip Blank 0 Air <7.0 n/a 0 0 NA'^> NA<2> a H

> Key: s * Sample volume (liters) is below recommended limit for the TEM method; volume is based on pump reading o ** Structure (S) is roughly equivalent to fiber (f) *** Chrysotile to **“Amosite NA - Not analyzed due to overloading of particulates W M NA® - Not analyzed for TEM G n/a - Not applicable H NC - Sample not collected to NS - Sample not submitted o o NIOSH 7400: Fiber Analysis of Air samples via NIOSH 7400, Revision 3, Issue 2, 8/15/94 co Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) EPA 40CFR Part 763 (AHERA) O Standard criteria; EPA 40CFR Part 763 (AHERA): 0.01 fiber/cc (PCM), 70 S/mm^ volume 1200 L, for 25 mm filter (TEM) H K I to

s o o o I o o FK-12-26-01-am o co co co

NYC-WTC_000248162

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000248162Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →