NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 3 pages

Residential air and dust sampling plan, lower Manhattan

Machine-extracted title · confidence 47%

ATSDR-supported plan to sample residential air and dust in lower Manhattan, Sept–Oct 2001.

NYC-WTC_000454701–000454703
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Air Sample Results

• The air samples from inside the buildings showed no elevated levels of asbestos. Levels were similar to those seen in areas not affected by the World Trade Center collapse. Dust Sample Results

Asbestos

Low levels of asbestos were found in settled dust, primarily below Chambers Street, in 11 (19 %) of the residential units dust sampled, 5 (19.2 %) of the common area samples and 5 (33 %) of the outdoor areas samples. Two of the outdoor samples met the requirements for asbestos abatement and these areas were cleaned up. • Asbestos was detected in some of the areas previously cleaned. • No asbestos was detected in the background dust samples taken from north of 59th Street. • Settled dust samples were analyzed using Polarized Light Microscopy or PLM. PLM identifies and distinguishes types of fibers, including asbestos or fibrous glass, by shape and the pattern/color of their appearance. TEM, a more sensitive form of analysis, was conducted as an additional check on all dust samples in which PLM testing did not detect levels of asbestos. Fibrous glass and other contaminants

• Fibrous glass was detected in settled dust samples from 23 (40.4%) of the residential unit samples, 11 (42.3%) of the common area samples, and 9 (64.3%) of the outside samples. The percentage of fibers in indoor samples that were fibrous glass ranged from 2% to 35%. • No fibrous glass was detected in background dust samples. • Fibrous glass was detected in many of the locations previously cleaned. • Samples continue to be analyzed for other contaminants, including crystalline silica, mica, gypsum, and calcite, as well as the total amount of dust and fibrous glass in the air. Health Implications of Findings/Recommendations

• Exposure to fibrous glass is known to cause rashes and upper respiratory irritation. These sampling results suggest that fibrous glass should be considered in choosing the mode and frequency of clean up. The negative air data and low levels of asbestos in dust suggest that clean up practices seem to be largely effective in eliminating asbestos exposure. • Although both the asbestos and fibrous glass were found in dust, both types of particles can become airborne if disturbed. Therefore, ATSDR is recommending that people continue to conduct frequent cleaning with HEPA vacuums and damp cloths/mops to reduce the potential for exposure in accordance with NYC Department of Health guidance. • ATSDR is recommending additional monitoring of residential units in lower Manhattan.

CITY_21MC100_008757803

NYC-WTC_000454702

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000454702Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000321766

ATSDR-assisted NYC sampling plan for Lower Manhattan residences; public health goals.

Similar indexed content

Compare copies and versions →