Final report draft: airborne/dust exposure

Machine-extracted title · confidence 36%

Draft final report assessing potential exposures to airborne and settled dust.

NYC-WTC_000320601–000320614
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

|fNancy Jeffery - Residential Sampling Final Report Draft 4 01 .wpd Page 91|

Draft; Do not Cite, Quote, or Release April 1, 2002

analysis was ‘overloaded’ with material, the TEM analysis indicated fiber count of <.006 f/cc; and no asbestos fibers were counted.

Two air samples from the common areas had results ranging from .004 to .005 f/cc. In both cases, no asbestos fibers were detected in the area's settled dust by PLM. In one case, the lab could not provide TEM results for the dust; TEM air analysis did not detect asbestos fibers in the air. In the second case, no asbestos fibers were detected in the settled dust by TEM.

Four air samples from three different residential units had results ranging from .005 - .012 f/cc. The TEM analysis for each sample indicates less than .001 fibers of asbestos/cc. The dust results did not detect asbestos by PLM in any of these units. The TEM results from two units did not detect asbestos.

None of the 32 air samples were taken from 29 different outdoor areas samples had airborne fiber concentrations greater than .003 f/cc.

Dust sample results

Asbestos Low levels of asbestos were found in settled dust, primarily below Chambers Street (found in 9 (15.8 %) of the residential units dust sampled, 5 (19.2 %) of the common area samples and 6 (42.8 %) of the outdoor areas samples). Asbestos was detected in areas previously cleaned. No asbestos was detected in the background dust samples taken from north of 59”’ Street.

Fibrous glass and other contaminants Fibrous glass was detected in settled dust samples from 23 (40.4%) of the residential units sampled, 11 (42.3%) of the common area samples, and 9 (64.3%) of the outside samples. No fibrous glass was detected in background dust samples. Fibrous glass was detected in locations previously cleaned.

LIMITATIONS The sampling plan was designed to obtain samples from locations across the lower Manhattan area. Because of the time urgency associated with the need to obtain results, the plan was not designed to gamer samples statistically representative of the area, but rather to give public health officials and citizens relatively quick, overall feedback regarding contaminants present.

ATSDR focused on contaminants that were known to have emanated from the collapse of the Trade Center towers that might cause health problems. However, our investigation

CITY_21MC100_006729685

NYC-WTC_000320609

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000320609Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →