Jan 29, 2002: summary of asbestos results for 34 buildings in NYC residential sampling.

NYC-WTC_000321709–000321711
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

- Background buildings, airborne fiber concentrations ranged from less than .001 to .003 f/cc

- 127 Air samples were taken from 117 different areas of the Lower Manhattan buildings, complete results are available for 126 of the samples - 10 Areas had co-located sampling equipment - 6 Air samples, in 5 areas, had concentrations greater than .003 f/cc by PCM - Those samples were all reanalyzed by TEM - TEM analysis for all of these samples indicates <.001 asbestos fibers/cc - 1 Air sample was possibly affected by nearby construction activities - PCM analysis was ‘overloaded’ - TEM analysis indicated ‘<.006 f/cc’ - No asbestos fibers were counted

- Common Areas - 30 Air samples were taken from 29 different common areas - 2 Of these samples had results ranging from .004 to .005 f/cc - In both cases, no asbestos fibers were detected in the area’s settled dust by PLM, - In one case the lab could not provide TEM results for the dust; TEM air analysis did not detect asbestos fibers in the air - In the second case, no asbestos fibers were detected in the settled dust by TEM; TEM air analysis did not detect asbestos fibers in the air - 1 Sample from this area was possibly affected by dust from nearby construction - PCM analysis was overloaded by unknown fibers - TEM analysis detected asbestos fibers in the air (<.006 f/cc) - No asbestos fibers were counted

- Residential Units - 64 Air samples were taken from 59 different residential units - 4 Air samples from 3 different residential units had results ranging from .005 - .012 f/cc - TEM analysis for each sample indicates less than .001 fibers of asbestos/cc - Dust results indicate that asbestos was not detected by PLM in any of these units - Dust TEM results only available for 2 units and indicates asbestos not detected

- Outdoor Areas - 32 Air samples were taken from 29 different outdoor areas - None of these samples had airborne fiber concentrations greater than .003 f/cc

CITY_21MC100_0030 52088

NYC-WTC_000321711

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000321711Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000301161

Table summarizing asbestos results by building number and status codes as of Jan 22, 2002.

Similar indexed content

NYC-WTC_000301133

Table summarizing asbestos results by building number and status codes as of Jan 22, 2002.

Similar indexed content

Compare copies and versions →