NYC-WTC_000319046
Summary table of asbestos results by building; status codes explained.
2 shared non-person entities · 1 shared topics · similarity 0.981
machine-extracted · confidence unavailable · Check page ↗Table summarizing asbestos results by building as of Jan 22, 2002.
NYC-WTC_000250981–000250991OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
FEB-0e-2002 17:06 NYC DOH LPPP SURU & RES 1 212 676 6326 P.04/17
- Background buildings, airborne fiber concentrations ranged from less than .001 to .003 f/cc
-127 Air samples were taken from 117 different areas of the Lower Manhattan buildings, complete results are available for 126 of the samples -10 Areas had co-located sampling equipment - 6 Air samples, in 5 areas, had concentrations greater than .003 f/cc by PCM - Those samples were all reanalyzed by TEM - TEM analysis for all of these samples indicates <.001 asbestos fibers/cc -1 Air sample was possibly affected by nearby construction activities - PCM analysis was ‘overloaded’ - TEM analysis indicated ‘<.006 f/cc’ - No asbestos fibers were counted
- Common Areas - 30 Air samples were taken from 29 different common areas - 2 Of these samples had results ranging from .004 to .005 f/cc - In both cases, no asbestos fibers were detected in the area’s settled dust by PLM, - In one case the lab could not provide TEM results for the dust; TEM air analysis did not detect asbestos fibers in the air - In the second case, no asbestos fibers were detected in the settled dust by TEM; TEM air analysis did not detect asbestos fibers in the air -1 Sample from this area was possibly affected by dust from nearby construction - PCM analysis was overloaded by unknown fibers - TEM analysis detected asbestos fibers in the air (<.006 f/cc) - No asbestos fibers were counted
- Residential Units - 64 Air samples were taken from 59 different residential units - 4 Air samples from 3 different residential units had results ranging from .005 - .012 free - TEM analysis for each sample indicates less than .001 fibers of asbestos/cc - Dust results indicate that asbestos was not detected by PLM in any of these units - Dust TEM results only available for 2 units and indicates asbestos not detected
- Outdoor Areas - 32 Air samples were taken from 29 different outdoor areas - None of these samples had airborne fiber concentrations greater than .003 f/cc
NYC-WTC_000250983
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000319046
Summary table of asbestos results by building; status codes explained.
2 shared non-person entities · 1 shared topics · similarity 0.981
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000318613
Table detailing sampling status and results by building number as of Jan 7, 2002.
2 shared non-person entities · 1 shared topics · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000301154
Laboratory summary of asbestos results across multiple tests and co-located samples.
1 shared non-person entities · 1 shared topics · similarity 0.975
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000263393
Summary table of asbestos test results with various methods.
1 shared non-person entities · 1 shared topics · similarity 0.973
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000320661
Table listing asbestos results by building with coding for non-detects and lab status.
2 shared non-person entities · 1 shared topics · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000320579
Draft outline for ambientdust/air evaluations at WTC, including sampling plan.
3 shared non-person entities · similarity 0.951
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000242808
Ambient dust evaluation with TEM/PLM decision rules for asbestos-containing material.
3 shared non-person entities · similarity 0.948
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000320589
Dust and air sampling protocol with TEM/PLM criteria and action thresholds.
3 shared non-person entities · similarity 0.947
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000321709
Jan 29, 2002: summary of asbestos results for 34 buildings in NYC residential sampling.
2 shared non-person entities · similarity 0.946
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000301133
Table summarizing asbestos results by building number and status codes as of Jan 22, 2002.
2 shared non-person entities · similarity 0.946
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000390030
Environmental evaluations comparing dust/air levels to indoor asbestos standards post-9/11.
3 shared non-person entities · similarity 0.947
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000390036
Dust/air evaluation report comparing impacted vs non-impacted areas; indoor standards reference.
3 shared non-person entities · similarity 0.946
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000319046
Summary table of asbestos results by building; status codes explained.
Similar indexed content
NYC-WTC_000318613
Table detailing sampling status and results by building number as of Jan 7, 2002.
Similar indexed content
NYC-WTC_000301154
Laboratory summary of asbestos results across multiple tests and co-located samples.
Similar indexed content
NYC-WTC_000263393
Summary table of asbestos test results with various methods.
Similar indexed content
NYC-WTC_000320661
Table listing asbestos results by building with coding for non-detects and lab status.
Similar indexed content