1.0 INTRODUCTION
The NYC DDC Infrastructure programs have been hampered due to soil and
groundwater quality conditions that present a health and safety concern and the need for
effective waste management. The efficiency of a protocol to deal with these issues and
present the field conditions to contractors prior to the inception of a bid is crucial to
allowing infrastructure projects to be completed in a safe, healthful, and cost efficient
manner. An environmental test-boring program to evaluate soil and groundwater quality
within the infrastructure corridor may be an effective means to achieve this goal.
There are several ways in which soil and groundwater may be impacted by
contaminants. The common impacts (petroleum/chemical spills and poor quality fill soil)
are distinct in the concerns they present in the respective media (soil or groundwater).
The types of impacts are therefore best examined separately by media and by the nature
in which they were impacted. Petroleum/chemical spills and fill soil, which may contain
coal, ashes, and cinders are common sources that impact soil and groundwater quality.
The types of compounds/elements associated with these sources include; volatile organic
compounds (VOCs), semi-volatile organic compounds (SVOCs), polychlorinated
biphenyl’s (PCBs) and heavy metals.
Pesticides and herbicides are other common soil and groundwater contaminants,
but they are not expected to be present in an urban environment. Therefore, their
presence does not need to be addressed unless there is reason to believe otherwise.
2.0 PRELIMINARY PHASE IN EVALUATING THE CONDITION
OF A CORRIDOR
DDC Staff should inspect and note the potential for current environmental
concerns within an infrastructure corridor associated with land use such as: gasoline
stations, automobile body/engine repair shops, dry cleaners, industrial manufacturing
facilities, rail yards, salvage yards and energy generation plants/substations. The results
if the field inspection should be recorded and transmitted to EHSS staff to be used in
development of an environmental sampling program.
3.0 SOIL QUALITY
3.1 SOIL IMPACTED BY PETROLEUM AND CHEMICAL
SPILLS
Soil which is impacted by a petroleum or chemical spill will typically exhibit
evidence (staining, discoloration, odor) of such impact. A photo-ionization detector
(PID) is a field instrument that is used to qualitatively detect the presence of VOCs
resulting from a petroleum or chemical spill. The PID can detect petroleum/chemical