SECTION 02082
Hygiene and who is currently certified by that board.
22. Certified Safety Professional (CSP): Individual having a bachelor's degree from
an accredited college or university and a minimum of four years experience as a
safety professional and who has successfully completed both levels of the
examination administered by the Board of Certified Safety Professionals and who
is currently certified by that board.
23. Clean Room: An uncontaminated area or room that is part of worker
decontamination enclosure system with provisions for storage of workers' street
clothes and protective equipment.
24. Clearance Air Monitoring: Employment of aggressive sampling techniques with a
volume of air collected to determine the airborne concentration of residual fibers
and shall be performed as the final abatement activity.
25. Commissioner: Commissioner of the NYCDEP.
26. Curtained Doorway: Device that consists of at least three overlapping sheets of
polyethylene over an existing or temporarily framed doorway. One sheet shall be
secured at the top and left side, the second sheet at the top and right side, and the
third sheet at the top and left side. All sheets shall have weights attached to the
bottom to ensure that the sheets hang straight and maintain a seal over the
doorway when not in use.
27. Decontamination Enclosure System: Series of connected rooms, separated from
the Work Area and from each other by air locks, for the decontamination of
workers, materials, waste containers, and equipment.
28. Department: NYCDEP.
29. Encapsulant (sealant) or Encapsulating Agent: Eiquid material which can be
applied to ACM and which temporarily controls the possible release of asbestos
fibers from the material either by creating a membrane over the surface (bridging
encapsulant) or by penetrating into the material and binding its components
together (penetrating encapsulant). This may also be used to seal surfaces from
which ACM has been removed.
30. Encapsulation: Coating or spraying of ACM with a sealant.
31. Enclosure: Construction of airtight walls and/or ceilings between ACM and the
facility environment, or around surfaces coated with ACM, or any other
appropriate procedure as determined by the Department which prevents the
release of asbestos fibers.
32. EEAP: Environmental Eaboratory Approval Program administered by the New
York State Department of Health.