Memo TO: Diane Smith, Project Director (Health Unit)

FROM: Mohammad Azam, Project Manager(HAZMAT Unit)

SUBJECT: Dean Street Family Center, 2155 Dean Street, Brooklyn Fagade and Parapet repair - Project # HHFACADE.2

DATE: 12-22-1999

On December 16, 1999 a limited asbestos investigation was performed at specific areas of concern which will be affected by the proposed renovations to the base flashing, parapet flashing, coping stone caulking, exterior waterproofing, lintel caulking, window caulking; and wall/ceiling materials in Apt#4A at the facility referenced above in order to assess the presence and conditions of ACM (Asbestos Containing Material) being impacted by the facade and parapet repairs. The scope of the proposed renovation plan was established during the pre-construction assessment meeting. This survey was based on request and the information data provided by the Health Unit on this facility.

Representative bulk samples of all suspect and accessible materials which are scheduled to be disturbed during the construction phase were collected and analyzed by means of PLM (Polarized Light Microscopy) and/or by TEM (Transmission Electron Microscopy) as required. Representative samples of the following materials were taken: base flashing, parapet flashing, exterior waterproofing, lintel caulking, window caulking, gypsum wall and gypsum ceiling. Upon analysis, the following materials were found to contain asbestos greater than 1%.

LOCATION MATERIAL/DESCRIPTION SAMPLE # ACM

Roof Parapet Flashing 991217b-827 10% Chry. Base Flashing- P‘ layer 991217b-831 10% Chry. Base Flashiiig-2'’'' layer 991217b-832 9% Chry.

Page 1 of 2

Specific results of all test analysis are attached for your information. Attached here is the unit price budgetary abatement cost estimate for the above ACM materials and the ACP-7 form.

CITY_21MC100_008086324

NYC-WTC_000454326

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000454326Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →