«■ Bulk Asbestos Test Report Taylor environmental grour inc. Test Method: EPA 600/R-93/116 ELAP #10928 Client: NYC School Construction Authority Date Received: 12/14/02 30-30 Thomson Avenue Date Analyzed: 12/14/02 Long Island City, N.Y. 11101 Analyst: Re: 90 Trinity Place LLW#: Report Ref: M894-14630

Laboratory Number 35151 35152 35153 35154 Sample Reference 1A 2A 3A IB Gross Sample Color Gray^ Gray Gray White Appearance Homogeneous Yes Yes Yes Yes w G Fibrous Yes Yes Yes Yes ro G Asbestos Found No No Yes Yes M O H Type{s) & Chrysotile H Percentage(s) of Amosite 8.7 28.8 O Asbestos Found Crocidolite G ?d Other o H M (Actinolite, Tremolite, Anthophyllite) O O H O Total Asbestos Found ND ND 8.7 28.8 < G Other Fiberglass 20 30 23.9 5.8 M H a Fibrous Cellulose <1.0 <1.0 o M ?d s a H Materials Synthetic Non-Fibrous Carbonates S ' Materials Silicates o Binder 80 70 67.4 65.4 to Location: Mechanical Room B11 Mechanical Room B11 Mechanical Room B11 Mechanical Room B11 w Steam Pipes Steam Pipes Steam Pipes Steam Pipes M

H TSI Fitting Insulation TSI Fitting Insulation TSI Fitting Insulation TSI Fitting Insulation INC = Inconclusive Gray Gray Gray White to o ND = None Detected co NG = None Given O H ** Residual weight of sample is <1.0% of original subsample weight; no further analysis is necessary. K * Polarized light microscopy is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Before I

o I this material can be considered or treated as non-asbestos-containing, confirmation must be made by quantitative transmission electron microscopy. 1) The results represented in this test report relate only to the samples tested. 2) This test report shall not be reproduced except in full, without the written approval of Taylor Environmental Group, Inc. o Io This report must not be used by the client to claim product endorsement by NVLAP or any agency of the US Government. Page 4 of 4 o co CD 130A JERICHO TPKE., FLORAL PARK, NY 11001 ■ PHONE (516) 358-2955 ■ FAX (516) 358-1780 cn o co

NYC-WTC_000453449

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000453449Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →