QAPP AMENDMENT FORM: Issue 2

The E-BAM flow calibration and flow audit criteria listed in the SOP were changed. An additional accuracy check on the How audit was introduced.

Reason for Amendment: The E-BAM flow audit and flow calibration criteria listed in the SOP were modified to be in accordance with EPA requirements found in the Reference QA Guidance Document, Volume II of Handbook, Section 2.12, Monitoring PM2.5 in Ambient Air Using Designated Reference Methods or Class I Equivalent Methods, November 1998. Section 13.1 of this reference discusses the flow rate audit criteria which require the accuracy of the flow rate to be within ±4% of the value indicated by the flow audit device and within ±5% of the sampler required flow rate of 16.67 liters per minute.

Sections of QAPP Affected: Attachment C, SOP for Met One E-BAM Particulate Monitor. Section 4.2: This section of the SOP has been revised to require that the flow rate be within ±4% (and not +2%) of the value indicated by the flow audit device. In addition, the requirement for the flow rate of the E-BAM to be within ±5% of the designated flow rate of 16.67 liter per minute has been introduced. This SOP has been reissued as Revision 1, February 2006. Attachment C, SOP for Met One E-BAM Particulate Monitor. Section 4.3: This section of the SOP has been revised to require that the flow rate be within ±4% (and not ±2%) of the value indicated by the flow audit device. This SOP has been reissued as Revision 1, February 2006.

Date Implemented: January 2006 (Phase I)

Including media in line during the flow rate check of the PCB pump is now an option in the SOP instead of a requirement.

Reason for Amendment: In order to determine the effect of the removal of media in line during the flow rate check, flow rates of all pumps were checked with and without media in line. The change in the flow rate was negligible, thereby justifying the flow rate check without the media in line. The data for these flow rate verifications with and without media are on file at TRC.

Sections of QAPP Affected: Attachment C, SOP for SKC Leland Legacy Pump for PCBs, Section 4.1: This section of the SOP has been revised to make the inclusion of media in line during the flow rate check an optional procedure. This SOP has been reissued as Revision 1, February 2006.

Date Implemented: January 2006 (Phase I)

Pages of?

CITY_21MC100_009193910

NYC-WTC_000451398

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000451398Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000427863

QAPP amendment to raise mercury spike from 50 ng to 150 ng for improved recoveries.

Similar indexed content

NYC-WTC_000446799

QAPP amendment documenting mercury spike level increase from 50 to 150 ng.

Similar indexed content

NYC-WTC_000441952

QAPP amendment changing mercury spike level from 50 to 150 ng in 2005.

Similar indexed content

Compare copies and versions →