particulate mass concentration of PM-10 in real time. The instrument has the USEPA
equivalency designation for PM-10 as EQPM-1090-079. Measured values and
identification of flags indicating any anomalies are recovered by the operator by
downloading a sample summary to a laptop or handheld computer.
10.2.9.2 PMio - Continuous Monitoring ofPMw via Met One E-BAM Samplers
The monitors selected to continuously measure PMio are beta-attenuation monitors
manufactured by Met One Instruments, Inc. (Met One). The E-BAM monitors will be
equipped with particle size selective inlets. The design of the inlets is such that particles
larger than the desired size range will be removed from the air flow at the prescribed air
flow rate. The units will be equipped with an inlet head to separate PMio. Sampling flow
rate is critical to maintain the proper particle size cut points of the inlets. Flow rates are
maintained at 16.7 liters per minute in the E-BAM monitors using an integral flow meter,
pressure sensor, and ambient temperature sensor on board each monitor.
10.2.10 PM2.5
PM2.5 will be determined by two separate methods. At each location, PM2.5 will be
determined by a non-reference method utilizing Met One’s E-BAM Mass Monitor, which
is a real-time monitor. A Rupprecht & Patshinck TEOM Series 1400a monitor measuring
the ambient particulate mass concentration of PM-2,5 in real time will be operated at one
location each day. The TEOM sampler will be collocated along side the E-BAM PM2,5
monitors as a QA check. The TEOM sampler will rotate on a bi-weekly basis through all
real-time PMio monitor locations for the duration of the monitoring program.
10.2.10.1 PM2.5 - Reference Method via Rupprecht & Patshinck TEOM Series 1400a
Monitor
Rupprecht & Patshinck TEOM Series 1400a monitor with a sharp-cut {M2.5 cyclone will
measure the ambient particulate mass concentration of PM-2.5 in real time. Measured
values and identification of flags indicating any anomalies are recovered by the operator
by downloading a sample summary to a laptop or handheld computer.
10.2.10.2 Continuous Monitoring 0/PM2.5 via Met One E-BAM Samplers
The monitors selected to continuously measure PM2.5 are beta-attenuation monitors
manufactured by Met One Instruments, Inc. (Met One). The E-BAM monitors will be
equipped with particle size selective inlets. The design of the inlets is such that particles
larger than the desired size range will be removed from the air flow at the prescribed air
flow rate. The units will be equipped with an inlet head to separate PM2.5. Sampling flow
rate is critical to maintain the proper particle size cut points of the inlets. Flow rates are
maintained at 16.7 liters per minute in the E-BAM monitors using an integral flow meter,
pressure sensor, and ambient temperature sensor on board each monitor.