NYC-WTC_000425341
QAPP amendment detailing calibration and flow-rate procedures for metals samplers; dated 4/5/06.
16 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗QAPP amendment detailing flow rate and calibration changes for high-volume samplers, submitted 2006.
NYC-WTC_000451394–000451399OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
QAPP AMENDMENT FORM: Issue 2
Weekly flow rate checks of low-flow sampling pumps for asbestos, mercury, PCBs, and silica will be replaced with daily checks. A criterion of < 20 will be introduced for the RPD between the initial and final flow rate readings. Reason for Amendment: Since the flow rates are verified on a daily basis, the weekly flow checks are redundant and therefore have been eliminated. In order to assess the precision of sample collection, the RPD criterion for initial and final flow rate readings has been introduced as a means of evaluating initial and final flow differences. This evaluation will serve as an additional measure to verify the accuracy of the reported volumes. If RPDs are greater than 20, associated data will be flagged as estimated. This criterion is consistent with the high-volume pump daily flow rate checks. Sections of QAPP Affected: 13.1.1, Field Equipment, Page 89, Asbestos, Mercury, and PCBs using a Personal Sampling Pump: The second bullet will be changed to reflect the performance of the flow rate verification on a daily basis instead of a weekly basis. An RPD criterion of < 20 will be introduced as a means of evaluating the initial and final flow rate readings. The corrective action will be to flag the associated data as estimated if the RPD criterion is exceeded. 13.1.1, Field Equipment, Page 90, Respirable Silica using a Personal Sampling Pump: The second bullet will be changed to reflect the performance of the flow rate verification on a daily basis instead of a weekly basis. An RPD criterion of < 20 will be introduced as a means of evaluating the initial and final flow rate readings. The corrective action will be to flag the associated data as estimated if the RPD criterion is exceeded. Date Implemented: January 2006 (Phase I)______________________________________________________________________
Two new field spike compounds, -chrysene and ' f ’e-dibcnziajijanlhraccnc, were added to the PAH sampling media to replace the one field spike compound ^^Ce-Huorene. The recovery limits for the new field spike compounds will be consistent with the field spike recovery requirements currently listed in Table 8-3 in the QAPP. Reason for Amendment: The field spike compound originally used and listed in the QAPP, 'T ’. -nuorcnc, was exhibiting low recoveries; these recovery data ,however, while lower than expected were generally found to be within the acceptable range defined in Table 8-3 of the September 7 2005 QAPP (i.e., 66% of the data exhibited acceptable recoveries). After review of the data, it appeared that the low recovery of the field spike was isolated to the field spike compound and did not affect the target compounds or extraction surrogates. The decision was made to use less volatile compounds for the field spikes which eluted in the range of the carcinogenic PAHs being analyzed for this program. These new compounds are more representative of the behavior of the target PAHs during the sample collection and analysis process. As a result, two new field spike compounds were chosen. Sections of QAPP Affected: Table 8-3: The field spike compounds will be changed as described above. Date Implemented: November 2005 (Phase 1)
Pages of?
CITY_21MC100_009193908
NYC-WTC_000451396
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000425341
QAPP amendment detailing calibration and flow-rate procedures for metals samplers; dated 4/5/06.
16 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000427863
QAPP amendment to raise mercury spike from 50 ng to 150 ng for improved recoveries.
6 shared non-person entities · 1 shared topics · similarity 0.924
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000425322
QAPP amendment modifying mercury spike level to 150 ng for field samples, Oct 2005.
6 shared non-person entities · 1 shared topics · similarity 0.924
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000446799
QAPP amendment documenting mercury spike level increase from 50 to 150 ng.
6 shared non-person entities · 1 shared topics · similarity 0.923
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000441952
QAPP amendment changing mercury spike level from 50 to 150 ng in 2005.
6 shared non-person entities · 1 shared topics · similarity 0.923
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000423693
QAPP amendment increasing mercury spike level from 50 to 150 ng/trap for improved accuracy.
7 shared non-person entities · similarity 0.918
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000451189
QAPP amendment updating mercury spike level from 50 ng to 150 ng.
7 shared non-person entities · similarity 0.916
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000443742
Chain-of-custody form for Environmental Community Air Monitoring Program plans at Greenwich Street and Thames Street, dated November 4, 2005.
16 shared non-person entities · similarity 0.916
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000444945
Plan and submittals for environmental community air monitoring at 133-135 Greenwich and 21-23 Thames.
16 shared non-person entities · similarity 0.915
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000440780
Plan document for environmental air monitoring at Greenwich Street and Thames Street sites, dated November 4, 2005.
16 shared non-person entities · similarity 0.915
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000447434
Chain of custody plan for Greenwich Street/Thames Street site air monitoring.
16 shared non-person entities · similarity 0.915
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000426348
Plan document outlining community air monitoring for Greenwich and Thames sites.
16 shared non-person entities · similarity 0.914
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000425341
QAPP amendment detailing calibration and flow-rate procedures for metals samplers; dated 4/5/06.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000425341
QAPP amendment detailing calibration and flow-rate procedures for metals samplers; dated 4/5/06.
Similarity score 0.944 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000447891
QA plan for ambient air monitoring at 130 Liberty Street, Sept 7, 2005.
Similarity score 0.944 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000447031
QA plan document for ambient air monitoring program for Liberty Street deconstruction.
Similarity score 0.944 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000449908
QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, Sept 7, 2005.
Similarity score 0.944 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000448520
Quality assurance plan for ambient air monitoring during deconstruction at Liberty Street.
Similarity score 0.943 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000425341
QAPP amendment detailing calibration and flow-rate procedures for metals samplers; dated 4/5/06.
Similar indexed content
QAPP amendment to raise mercury spike from 50 ng to 150 ng for improved recoveries.
Similar indexed content
NYC-WTC_000425322
QAPP amendment modifying mercury spike level to 150 ng for field samples, Oct 2005.
Similar indexed content
QAPP amendment documenting mercury spike level increase from 50 to 150 ng.
Similar indexed content
QAPP amendment changing mercury spike level from 50 to 150 ng in 2005.
Similar indexed content