QAPP amendment form, Liberty Street, 2005

Machine-extracted title · confidence 40%

QAPP amendment detailing flow rate and calibration changes for high-volume samplers, submitted 2006.

NYC-WTC_000451394–000451399
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

QAPP AMENDMENT FORM: Issue 2

Weekly flow rate checks of low-flow sampling pumps for asbestos, mercury, PCBs, and silica will be replaced with daily checks. A criterion of < 20 will be introduced for the RPD between the initial and final flow rate readings. Reason for Amendment: Since the flow rates are verified on a daily basis, the weekly flow checks are redundant and therefore have been eliminated. In order to assess the precision of sample collection, the RPD criterion for initial and final flow rate readings has been introduced as a means of evaluating initial and final flow differences. This evaluation will serve as an additional measure to verify the accuracy of the reported volumes. If RPDs are greater than 20, associated data will be flagged as estimated. This criterion is consistent with the high-volume pump daily flow rate checks. Sections of QAPP Affected: 13.1.1, Field Equipment, Page 89, Asbestos, Mercury, and PCBs using a Personal Sampling Pump: The second bullet will be changed to reflect the performance of the flow rate verification on a daily basis instead of a weekly basis. An RPD criterion of < 20 will be introduced as a means of evaluating the initial and final flow rate readings. The corrective action will be to flag the associated data as estimated if the RPD criterion is exceeded. 13.1.1, Field Equipment, Page 90, Respirable Silica using a Personal Sampling Pump: The second bullet will be changed to reflect the performance of the flow rate verification on a daily basis instead of a weekly basis. An RPD criterion of < 20 will be introduced as a means of evaluating the initial and final flow rate readings. The corrective action will be to flag the associated data as estimated if the RPD criterion is exceeded. Date Implemented: January 2006 (Phase I)______________________________________________________________________

Two new field spike compounds, -chrysene and ' f ’e-dibcnziajijanlhraccnc, were added to the PAH sampling media to replace the one field spike compound ^^Ce-Huorene. The recovery limits for the new field spike compounds will be consistent with the field spike recovery requirements currently listed in Table 8-3 in the QAPP. Reason for Amendment: The field spike compound originally used and listed in the QAPP, 'T ’. -nuorcnc, was exhibiting low recoveries; these recovery data ,however, while lower than expected were generally found to be within the acceptable range defined in Table 8-3 of the September 7 2005 QAPP (i.e., 66% of the data exhibited acceptable recoveries). After review of the data, it appeared that the low recovery of the field spike was isolated to the field spike compound and did not affect the target compounds or extraction surrogates. The decision was made to use less volatile compounds for the field spikes which eluted in the range of the carcinogenic PAHs being analyzed for this program. These new compounds are more representative of the behavior of the target PAHs during the sample collection and analysis process. As a result, two new field spike compounds were chosen. Sections of QAPP Affected: Table 8-3: The field spike compounds will be changed as described above. Date Implemented: November 2005 (Phase 1)

Pages of?

CITY_21MC100_009193908

NYC-WTC_000451396

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000451396Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000427863

QAPP amendment to raise mercury spike from 50 ng to 150 ng for improved recoveries.

Similar indexed content

NYC-WTC_000446799

QAPP amendment documenting mercury spike level increase from 50 to 150 ng.

Similar indexed content

NYC-WTC_000441952

QAPP amendment changing mercury spike level from 50 to 150 ng in 2005.

Similar indexed content

Compare copies and versions →