Quality Assurance Plan, Ambient Air Monitoring, LMDC

Machine-extracted title · confidence 39%

QA plan document for ambient air monitoring program for Liberty Street deconstruction.

NYC-WTC_000447031–000447162
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Ambient Air Monitoring Program Section No. 10 Quality Assurance Project Plan Revision No.: 0 1301 I berly Street - NY, NY Date: September 7, 2005 Lower Manhattan Development Coi-poration Page 72 of 124

The E-BAM monitors will be equipped with particle size selective inlets. The design of the inlets is such that particles larger than the desired size range will be removed from the air flow at the prescribed air flow rate. The units will be equipped with an inlet head to separate PM2.5. Sampling flow rate is critical to maintain the proper particle size cut points of the inlets. Flow rates are maintained at 16.7 liters per minute in the E-BAM monitors using an integral flow meter, pressure sensor, and ambient temperature sensor on board each monitor.

10.3 Field Quality Control

This section of the QAPP identifies the QC procedures, checks, samples, and their respective acceptance limits, that will be used to monitor the quality of various aspects of the sampling event. Their required analysis frequency, acceptance limits and corrective actions are also documented in this section of the QAPP.

10.3.1 Field Blanks/Trip Blanks

Field/trip blanks consist of clean sample media. Field/trip blanks accompany samples to the site and return to the laboratory in the same cooler or shipping container. Field/trip blanks will be used to ensure that there is no contamination as a result of the shipment/transportation/on-site storage activities. Field/trip blanks will be collected for all parameters associated with air samples. Field/trip blanks for asbestos and silica will only be analyzed if the asbestos or silica are detected in the associated samples.

10.3.2 Cooler Temperature Blanks

Cooler temperature blanks consist of a sample container filled with non-preserved water (potable or distilled) and are included in all coolers which contain samples which require temperature preservation (PAHs, PCBs, PCDDs/PCDFs). The laboratory uses these temperature blanks to ensure that proper preservation of the samples has been maintained during sample shipment. The temperature of these blanks must be 4 °C ±2° to demonstrate that proper preservation has been maintained. The laboratory records the results of the temperature blanks on the chain-of- custody or sample login form immediately upon receipt of the samples at the laboratory, prior to inventory and refrigeration.

10.3.3 Field Duplicates

Field duplicates will be collocated samples. Collocated samples are two samples collected next to each other in the same vertical position. Collocated samples require two separate sample collections at the same location. Field duplicates will be used to assess the sampling and analytical reproducibility. With the exception of total mercury, field duplicates will be submitted at a frequency of once per week per analytical parameter. For total mercury, field duplicates and field spikes will be alternated on a weekly basis.

10.3.4 Field Spikes

CITY_21MC100_003212818

NYC-WTC_000447103

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000447103Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000449908

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, Sept 7, 2005.

Similar indexed content

NYC-WTC_000447891

QA plan for ambient air monitoring at 130 Liberty Street, Sept 7, 2005.

Similar indexed content

NYC-WTC_000443239

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, LMDC.

Similar indexed content

NYC-WTC_000444248

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, Sept 2005.

Similar indexed content

Compare copies and versions →