Air and Wipe Sampling Schedule, Analytical Methods and Clearance Criteria
for
90 Church Street
Sample Sample Sampling Analytical Method # of Samples/ Clearance Primary Secondary
Parameter Description Methodology Work Area Criteria Laboratory Laboratory
Asbestos Air Samples AHERA (40CFR TEM Minimum five (5) + 1 70 s/mm^ SciLabs EMSL
763, Appendix A) per every 5000 sf. over (As set forth in the AHERA
25,000 sf. standard)
Fiberglass Air Samples NIOSH 7400 PCM Minimum three (3) + 1 0.01 f/cc SciLabs EMSL
(with SEM per every 10,000 sf.
confirmation, if over 25,000 sf.
necessary)
Viable Fungi Air Samples Andersen N6 Light Microscopy Minimum five (5) -r 1 Statistical comparison of P&K PathCon
Impactor with MEA per every 5000 sf. over types and counts Inside the Microbiology
plates 25,000 sf. Work Area vs. Outside
Silica Air Samples NIOSH 7500 XRD Three (3) 1.0 ug/m3 Analytics DataChem
Dioxin Wipe ASTM D6661-01 EPA SW-846-8290 1 per every 10,000 sf. <0.37 ng/fF Triangle Labs STL
Samples High Resolution with a minimum of 3 (2,3,7,8-TCDD TEQ)
GC/MS
Lead Wipe ASTM E1728-02 NIOSH 7300M 1 per every 2000 sf. <40 ug/fF - floors Analytics DataChem
Samples ICP with a maximum of 25 <250 ug/fF- sills
from both the floor and
window sills
Metals Wipe ASTM El 728-02 NIOSH 7300M 15% of the Lead wipes Sb - 465 ug/fF Analytics DataChem
Samples ICP with a minimum of 1 As - 1.86 ug/fF
Be - 0.47 ug/fF
Cd - 4.7 ug/fF
Cr - 465 ug/fF
Cu - 929 ug/fF
Ni - 14 ug/fF
Se-186 ug/fF
Ag - 9.29 ug/fF
o Zn - 4645 ug/fF
Mercury Wipe ASTM E1728-02 NIOSH 6009M 1 per every 10,000 st. <23 ug/fF Analytics DataChem
H
l"^ Samples Cold Vapor AA with a minimum of 3
to
s
O
PNAs Wipe
Samples
ASTM D6661-01 EPA SW-846-
8270C
1 per every 10,000 sf.
with a minimum of 3
<0.028 mg/fF Analytics DataChem
I—1
o HPLC/UV-FL
o
Io
o
co
to
l->
co
cn