NYC-WTC_000451139
Schedule for asbestos air and wipe sampling under AHERA/NIOSH methods.
11 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗Laboratory sampling plan detailing asbestos air and wipe methods for 90 Church Street, including sample counts and analytical methods.
NYC-WTC_000422883
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Air and Wipe Sampling Schedule, Analytical Methods and Clearance Criteria for 90 Church Street Sample Sample Sampling Analytical Method # of Samples/ Clearance Primary Secondary Parameter Description Methodology Work Area Criteria Laboratory Laboratory
Asbestos Air Samples AH ERA (40 CFR TEM Minimum five (5) + 1 70 s/mm^ SciLabs EMSL 763, Appendix A) per every 5000 sf. over (As set forth in the AH ERA 25,000 sf. standard) Fiberglass Air Samples NIOSH 7400 PCM Minimum three (3) -i-1 0.01 f/cc SciLabs EMSL (with SEM per every 10,000 sf. confirmation, if over 25,000 sf. necessary) Viable Fungi Air Samples Andersen N6 Light Microscopy Minimum five (5) + 1 Statistical comparison of P&K PathCon Impactor with MEA per every 5000 sf. over types and counts Inside the Microbiology plates 25,000 sf. Work Area vs. Outside Silica Air Samples NIOSH 7500 XRD Three (3) 1.0 ug/m3 Analytics DataChem
Dioxin Wipe ASTM D6661-01 EPA SW-846-8290 1 per every 10,000 sf. <0.37 ng/fF Triangle Labs STL Samples High Resolution with a minimum of 3 (2,3,7,8-TCDD TEO) GC/MS Lead Wipe ASTM El 728-02 NIOSH 7300M 1 per every 2000 sf. <40 ug/fF - floors Analytics DataChem Samples ICP with a maximum of 25 <250 ug/fF-sills from both the floor and windowsills O Metals Wipe ASTM El 728-02 NIOSH 7300M 15% of the Lead wipes Sb - 465 ug/fF Analytics DataChem Samples ICP with a minimum of 1 As - 1.86 ug/fF Be - 0.47 ug/fF o Cd - 4.7 ug/fF m Cr - 465 ug/fF Cu - 929 ug/fF Ni-14ug/fF o Se-186 ug/fF J] □0 Ag - 9.29 ug/fF Zn - 4645 ug/fF 'o > Mercury Wipe ASTM El 728-02 NIOSH 6009M 1 per every 10,000 sf. <23 ug/fF Analytics DataChem z Samples Cold Vapor AA with a minimum of 3
s c □0 PNAs Wipe Samples ASTM D6661-01 EPA SW-846- 8270C HPLC/UV-FL 1 per every 10,000 st. with a minimum of 3 <0.028 mg/fF Analytics DataChem
l"” o o o o tn o co r\o
NYC-WTC_000422883
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000451139
Schedule for asbestos air and wipe sampling under AHERA/NIOSH methods.
11 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000307895
Table of sampling methods for lead, PAHs, dioxin wipe samples; HUD/EPA methods listed.
7 shared non-person entities · similarity 0.936
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000186500
Notice of mandatory pre-bid meeting and background information regarding interior asbestos abatement and monitoring at 114 Liberty Street scheduled for February 2003.
6 shared non-person entities · similarity 0.932
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000205550
Document outlining mandatory pre-bid meeting and scope for interior asbestos cleaning and air monitoring at 114 Liberty Street.
6 shared non-person entities · similarity 0.931
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000279027
Bid items and labor rates for air monitoring and TEM/PCM analysis.
6 shared non-person entities · similarity 0.931
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000362544
Chain-of-custody form relating to dust sampling and asbestos abatement monitoring at 114 Liberty Street, Feb 2003.
6 shared non-person entities · similarity 0.930
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000342487
Chain-of-custody form for asbestos-related dust sampling at 114 Liberty Street, WTC site, facility-wide.
6 shared non-person entities · similarity 0.930
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000362702
Chain-of-custody entry referencing a pre-bid meeting and building walkthrough for WTC-LBA scope.
6 shared non-person entities · similarity 0.930
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000342508
Document outlining mandatory pre-bid meeting and scope for interior asbestos cleaning and air monitoring at 114 Liberty Street.
6 shared non-person entities · similarity 0.930
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000282430
Chain-of-custody/meeting notes for WTC-LBA project; pre-bid site walkthrough and background.
6 shared non-person entities · similarity 0.930
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000279035
Background on cleaning scope and on-site monitoring for asbestos abatement at 114 Liberty.
6 shared non-person entities · similarity 0.929
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000163360
Technical specifications for air quality monitoring work at two Manhattan buildings.
8 shared non-person entities · similarity 0.938
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000451139
Schedule for asbestos air and wipe sampling under AHERA/NIOSH methods.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000100690
Permit application for a licensed asbestos contractor to clean interior dust at the unoccupied 114 Liberty Street building.
Similarity score 0.974 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000342487
Chain-of-custody form for asbestos-related dust sampling at 114 Liberty Street, WTC site, facility-wide.
Similarity score 0.974 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000162898
Correspondence sharing monitoring specifications and related documents for the 114 Liberty Street site cleanup project.
Similarity score 0.974 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000282430
Chain-of-custody/meeting notes for WTC-LBA project; pre-bid site walkthrough and background.
Similarity score 0.974 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000206797
Contract scope detailing mandatory pre-bid meeting and requirements for licensed contractors to clean and monitor asbestos at 114 Liberty Street.
Similarity score 0.974 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000451139
Schedule for asbestos air and wipe sampling under AHERA/NIOSH methods.
Similar indexed content
NYC-WTC_000163360
Technical specifications for air quality monitoring work at two Manhattan buildings.
Similar indexed content
NYC-WTC_000307895
Table of sampling methods for lead, PAHs, dioxin wipe samples; HUD/EPA methods listed.
Similar indexed content
NYC-WTC_000186500
Notice of mandatory pre-bid meeting and background information regarding interior asbestos abatement and monitoring at 114 Liberty Street scheduled for February 2003.
Similar indexed content
NYC-WTC_000205550
Document outlining mandatory pre-bid meeting and scope for interior asbestos cleaning and air monitoring at 114 Liberty Street.
Similar indexed content