NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 2 pages

Asbestos air sampling, Staten Island, 2002

Machine-extracted title · confidence 43%

New York City asbestos air sampling results; PCM/TEM results for Staten Island site, May–June 2002.

NYC-WTC_000450636–000450637
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

NYC Response Asbestos Air Sampling Results for Staten island Landfiii Sampling Date and Time 5/31/20020732 to 6/01/02 0246 Date VaSidatioii Date; 06/04/20Q2

PCM by NiOSH 7400 ___________ TEM ( AHERA) Sampling Sampling Sample Structures (#) Date Sample No. Location Volume* Matrix f/mm^ f/cc O.Sp - 5p 5!4 S/mm" S~f/cc‘* 05/31/02 LF04978 P-1 1224.00 Air <7.0 <0.002 ...2 0 26.25 0.0083 05/31/02 LF04979 P-2 1296.00 Air 11.46 0.003 0 0 <15.75 <0.0047 05/31/02 LF04980 P-3 1296.00 Air 15.29 0.005 0 31.50 0.0094 05/31/02 LF04981 P-4 1296.00 Air 19.11 0.006 0 31.50 0.0094 05/31/02 LF04982 P-5 1368.00 Air 26.75 0.008 0 0 <15.75 <0.0044 05/31/02 LF04983 P-6 1214.10 Air <7.0 <0.002 0 0 <13.12 <0.0042 05/31/02 LF04984 P-7 1132.40 Air 14.01 0.005 0 ....l 13.12 0.0045 05/31/02 LF04985 P-8 1296.00 Air <7.0 <0.002 0 0 <15.75 <0.0047 05/31/02 LF04986 W-12A 1296.00 Air 7.64 0.002 0 0 <15.75 <0.0047 05/31/02 LF04987 W-12B 2050.20 Air 10.19 0.002 0 39.37 0.0074 05/31/02 LF04988 B-13 1296.00 Air <7.0 <0.002 0 0 <15.75 <0.0047 05/31/02 LF04989 T-15 1296.00 Air <7.0 <0.002 0 0 <15.75 <0.0047 05/31/02 LF04990 T-16 1296.00 Air 7.64 0.002 0 0 <15.75 <0.0047 05/31/02 LF04991 0-17 1101.60 Air 7.64 0.003 0 0 <13.12 <0.0046 05/31/02 LF04992 0-18 1296.00 Air <7.0 <0.002 0 0 <15.75 <0.0047 05/31/02 LF04993 0-19 1274.90 Air 10.19 0.003 0 0 <15.75 <0.0048 05/31/02 LF04994 MPHS-20 1296.00 Air 10.19 0.003 0 15.75 0.0047 05/31/02 LF04995 TS-21 1368.00 Air <7.0 <0.002 0 0 <15.75 <0.0044 05/31/02 LF04996 W-12 B Pup 1368.00 Air 14.01 0.004 0 0 <15.75 <0.0044 05/31/02 LF04997 Lot Blank 0.00 Air <7.0 n/a NA(=^> NA(=^> NA(=^> NA(=^> 05/31/02 LF04998 Trip Blank 0.00 Air <7.0 n/a NA<^> NA(=^> NA<=^> NA<=^>

Please note that Sample for Location W 12B ran for over 18 hours

Key; * Some sample volume (liters) are below recommended limit for the TEM method; volume is based on pump reading ** Structure (S) is roughly equivalent to fiber (f) *** Chrysotile **** Actinolite ““‘Amosite NA - Not analyzed due to overloading of particulates NA <=’ - Not analyzed for TEM NA - Not analyzed due to wet filter n/a - Not applicable NR - Not requested NS - Sample not submitted o R - Sample data rejected due to no sample volume H NC - Sample not collected NS - Sample not submitted to NiOSH 7400: Fiber Anaiysis of Air sampies via NIOSH 7400, Revision 3, issue 2, 8/15/94 S o Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) EPA 40CFR Part 763 (AHERA) Standard criteria: EPA 40CFR Part 763 (AHERA): 0.01 tiber/cc (PCM), 70 S/mm^ volume 1200 L, for 25 mm filter (TEM) o o Io Ln o to cn o cn ‘.C

NYC-WTC_000450636

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000450636Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →