NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Asbestos air sampling results, Staten Island, Jun 2002

Machine-extracted title · confidence 41%

Air sampling results for asbestos at Staten Island site in June 2002.

NYC-WTC_000436302
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

NYC Response Asbestos Air Sampling ResuSts for Staten island Landfiii Sampling Date and Time 6/22/20Q2Q827 to 6/23/Q2 0901 Date VaSidatioii Date; 05/25'2002

PCM by NiOSH 7400 ___________ TEM ( AHERA) Sampling Sampling Sample Structures (#) Date Sample No. Location Volume* Matrix f/mm^ f/cc O.Sp - 5p 5!^ S/mm" S~f/cc‘* 06/22/02 LF05400 P-1 1296.00 Air <7.0 <0.002 0 0 <15.75 <0.0047 06/22/02 LF05401 P-2 1296.00 Air <7.0 <0.002 0 0 <15.75 <0.0047 06/22/02 LF05402 P-3 1296.00 Air <7.0 <0.002 0 0 <15.75 <0.0047 06/22/02 LF05403 P-4 1332.00 Air <7.0 <0.002 0 0 <15.75 <0.0046 06/22/02 LF05404 P-5 1296.00 Air <7.0 <0.002 0 0 <15.75 <0.0047 06/22/02 LF05405 P-6 2269.80 Air <7.0 <0.001 0 0 <19.69 <0.0033 06/22/02 LF05406 P-7 1026.00 Air <7.0 <0.003 0 0 <13.12 <0.0049 06/22/02 LF05407 P-8 693.00 Air <7.0 <0.004 0 0 <11.25 <0.0063 06/22/02 LF05408 W-12A 1332.00 Air <7.0 <0.002 0 0 <15.75 <0.0046 06/22/02 LF05409 W-12B 1261.80 Air <7.0 <0.002 0 0 <15.75 <0.0048 06/22/02 LF05410 T-15 1296.00 Air <7.0 <0.002 0 0 <15.75 <0.0047 06/22/02 LF05411 T-16 1296.00 Air <7.0 <0.002 0 0 <15.75 <0.0047 06/22/02 LF05412 0-17 1359.65 Air <7.0 <0.002 0 0 <15.75 <0.0045 06/22/02 LF05413 0-18 1209.45 Air <7.0 <0.002 0 0 <13.12 <0.0042 06/22/02 LF05414 0-19 1296.00 Air <7.0 <0.002 0 0 <15.75 <0.0047 06/22/02 LF05416 Lot Blank 0.00 Air <7.0 n/a NA<^> NA<=^> NA<=^> NA<=^> 06/22/02 LF05417 Trip Blank 0.00 Air <7.0 n/a NA(^> NA® NA(=^> NA®

Note that sample for looation P-6 ran fo rover 20 hours No Sample submitted for Location MPHS-20 due to pump fault

Key: * Some sample volume (liters) are below recommended limit for the TEM method; volume is based on pump reading ** Structure (S) is roughly equivalent to fiber (f) *** Chrysotile **** Actinolite “"‘Amosite NA - Not analyzed due to overloading of particulates NA - Not analyzed for TEM NA - Not analyzed due to wet filter n/a - Not applicable NR - Not requested NS - Sample not submitted R - Sample data rejected due to no sample volume NC - Sample not collected NS - Sample not submitted O NiOSH 7400: Fiber Analysis of Air samples via NiOSH 7400, Revision 3, issue 2, 8/15/94 H Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) EPA 40CFR Part 763 (AHERA) Standard criteria: EPA 40CFR Part 763 (AHERA);0.0t tiber/cc (PCM), 70 S/nim\ volume 1200 L, for 25 mm filter (TEM) to s o o o I Ln o

to o to co wo

NYC-WTC_000436302

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000436302Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →